Nitrogen Glove Box
1)Acrylic Type A glove box: No sample transfer window, must be take it out from the door.
2)Acrylic Type B glove box:There is a sample transfer window, which can protect the gas environment inside the box from being damaged by the outside world.
3)Acrylic Type B glove box:The air in the box can be extracted through the vacuum pump, and then through the high purity dry inert gas into the box, and reach the lower water oxygen content in the box
2.Customization:
1)Single, double, multiple people and other different station boxes.
2)Different shapes, different structures, different applications, different thickness customization options.
3)Doors of different sizes can be opened on any side of the box to facilitate the entry and exit of equipment and accessories.
4)For other optional configurations, contact sales personnel.
***Price List for whole above, inquire us to get
Description
Technical Parameters
The nitrogen glove box is a widely used equipment in the laboratory, with excellent sealing performance, gas purity and control system. It can provide a pure, oxygen-free working environment for various experiments, help to protect experimental materials from contamination and oxidation, and improve the accuracy and repeatability of the experiment. The equipment takes advantage of the inert nature of nitrogen to filter out the active substances (such as oxygen, moisture, etc.) in the tank through circulation, thus creating a dry, oxygen-free working environment. It uses high-purity nitrogen, which usually requires water content less than 0.01ppm and oxygen content less than 0.01ppm to ensure the purity of the experimental environment. In addition, the equipment has excellent sealing performance, which can effectively prevent the intrusion of external gases and microorganisms, and protect the experimental materials from contamination. The equipment is usually equipped with advanced control systems that can monitor and adjust gas flow, pressure and purity in real time to ensure the stability of the atmosphere in the box and the safety of the working environment.
Specifications






application
In additive manufacturing and 3D printing, the integrity and quality of printed parts are paramount, especially when working with materials that are highly sensitive to environmental factors such as moisture and oxygen. A nitrogen glove box serves as an indispensable tool in this context, offering a precisely controlled environment that safeguards these materials from contamination and ensures the production of high-quality printed parts.
Protection Against Moisture and Oxygen
Moisture Sensitivity
Many 3D printing materials, particularly those based on metals, ceramics, or certain polymers, can react adversely with moisture. Moisture absorption can lead to material degradation, reduced mechanical properties, and defects in the printed parts. It maintains an ultra-low humidity environment, typically below 0.1% relative humidity, preventing moisture ingress and ensuring material stability.
Oxygen Sensitivity
Oxygen can cause oxidation in metal powders and certain reactive polymers, leading to changes in material properties and print quality. By purging the glove box with high-purity nitrogen, oxygen levels are reduced to trace amounts (often below 10 ppm), mitigating the risk of oxidation and preserving material integrity.
Applications in Specific 3D Printing Technologies
Powder Bed Fusion (PBF)
In metal PBF processes like Selective Laser Melting (SLM) or Electron Beam Melting (EBM), metal powders are highly sensitive to moisture and oxygen. It is used to handle and store these powders, ensuring their quality and printability.
Binder Jetting
In binder jetting processes, where a liquid binding agent is selectively deposited onto a powder bed, maintaining a dry and oxygen-free environment is crucial to prevent powder clumping and ensure proper binding.
Material Jetting and Aerosol Jetting
These processes often involve sensitive inks or suspensions that can be affected by moisture and oxygen. It provides a controlled environment for material preparation and printing.
Preparatory phase

Check the equipment
Make sure it is well sealed and leak-free.
Check the nitrogen supply system to ensure that the nitrogen flow and pressure are stable and meet the experimental requirements.
Check the control system of the glove box to ensure that parameters (such as gas flow, pressure, purity, etc.) are displayed and regulated properly.

Sterilization treatment
The equipment is thoroughly disinfected before use, usually using ultraviolet lamps or chemical disinfectants to disinfect its surface.
Ensure that all items entering the glove box (e.g. reagents, tools, samples, etc.) are sterile.

Prepare experimental materials
Prepare the reagents, tools, samples, etc. needed for the experiment and ensure that they have been properly sterilized.
Place these items in an easily accessible location outside the glove box of the device.
Enter the glove box

Wear personal Protective equipment
Wear aseptic clothing, gloves, masks and other personal protective equipment to ensure that no contamination is introduced during the experiment.
To enter the glove box
Enter the device through the mouth of the glove. Ensure the integrity of gloves to avoid breakage.
Use aseptic handling techniques to transfer required items from the outside of the box to the inside. This usually involves the use of sterile holding forceps or other sterile tools.

Experimental process
Adjust the experimental environment
According to the experimental requirements, the gas flow, pressure, purity and other parameters of the equipment are adjusted by the control system.
Ensure that the test environment meets the test requirements, such as temperature, humidity, etc.
To conduct an experiment
In this device, follow the experimental steps. Keep the operating area clean to avoid cross contamination.
Pay close attention to parameters such as gas flow, pressure and purity displayed by the control system to ensure the stability of the experimental environment.
Record data
In the course of the experiment, record the experimental data in time, including experimental conditions, observation results, etc.
Ensure the accuracy and completeness of the data for subsequent analysis and summary.
Post-termination treatment
Organize experimental items
Classify and dispose of used reagents, tools, samples, etc.
Items that need to be discarded should be placed in designated medical waste containers.
Cleaning and disinfection
Clean and disinfect it if necessary to ensure it remains clean and sterile the next time you use it.
Pay special attention to the cleaning and disinfection of the glove mouth to avoid the influence of residue on the next experiment.
Turn off the device
After all operations are completed and handled properly, turn off the control system and nitrogen supply system of the equipment.
Make sure the equipment is in a safe condition for next use.
Matters needing attention
Preparations before the operation
Familiar with equipment:
Before the first use, read the operating instructions carefully to understand the structure, performance, operation methods, and safety precautions of the device.
Check device status:
Check that the equipment is well sealed without leakage.
Check whether the nitrogen supply system works properly, including the nitrogen flow rate, pressure, and purity.
Check that the lighting, monitoring and alarm systems in the glove box are working properly.
Sterilization treatment:
Before use, the glove box is thoroughly sterilized to ensure the sterility of the experimental environment.
Precautions during operation




Wear personal Protective equipment:
Before entering the equipment, please wear personal protective equipment, such as sterile clothing, gloves, masks, etc., to prevent contamination and injury.
Maintain glove integrity:
During operation, keep the integrity of the gloves to avoid damage. If gloves are broken, replace them immediately.
Note the gas concentration:
Pay close attention to the concentration of gas in the box, especially the concentration of oxygen and harmful gases. If the concentration of oxygen is too low or the concentration of harmful gases is too high, the experiment should be stopped immediately and measures should be taken.
Avoid prolonged exposure:
Operators should avoid working in the box for a long time to avoid physical discomfort. If you need to work for a long time, take regular breaks and change the operator.
Note the order of operation:
When conducting experiments, the experimental procedures and operating procedures should be followed to avoid cross-contamination and misoperation.
Record experimental data:
In the course of the experiment, record the experimental data in time, including experimental conditions, observation results, etc. Ensure data accuracy and completeness.
Handling after operation
Organize experimental items
After the end of the experiment, the used reagents, tools, samples, etc. will be sorted out and properly disposed of. Items that need to be discarded should be placed in designated medical waste containers.
Cleaning and disinfection
Clean and disinfect it if necessary to ensure it remains clean and sterile the next time you use it. Pay special attention to the cleaning and disinfection of the glove mouth.
Turn off the device
When all operations are completed and handled properly, shut down its control system and nitrogen supply system. Ensure that the device is in a safe state.
Check device status
Before shutting down the device, check the sealing performance, the nitrogen supply system, and other related devices. If there is an anomaly, report it and handle it in time.
Technological principle
The nitrogen glove box serves as a vital instrument across numerous scientific and industrial domains by delivering a precisely controlled atmosphere. Its core function is to establish an environment devoid of reactive gases, primarily oxygen and moisture, which are often detrimental to sensitive processes and materials. By flooding the enclosed chamber with nitrogen, a chemically inert gas, the glove box efficiently displaces ambient air, thereby minimizing the presence of oxygen and water vapor. This creates a stable, oxygen-free or low-oxygen space that is essential for preventing oxidation, degradation, and unintended chemical reactions.
In fields like materials science, the glove box is indispensable for handling and studying materials that are highly reactive or susceptible to environmental changes. For instance, certain metals and alloys can oxidize rapidly when exposed to air, altering their properties and compromising research results. Similarly, in chemistry, the glove box enables the safe manipulation of air-sensitive compounds, facilitating reactions that would otherwise be impossible under normal laboratory conditions.
The electronics industry also heavily relies on nitrogen glove boxes, particularly in the manufacturing and testing of semiconductor devices and batteries. Even minute traces of oxygen or moisture can cause corrosion, short circuits, or reduced performance in these components. By using a glove box, manufacturers can ensure the integrity and reliability of their products, leading to improved quality and longevity.
In summary, the nitrogen glove box plays a critical role in maintaining the purity and stability of materials and processes, making it an invaluable asset in research and production environments where precision and control are paramount.
Hot Tags: nitrogen glove box, China nitrogen glove box manufacturers, suppliers, factory, Double Jacketed Glass Reactor, Jacketed Glass Reactor, Hydrothermal Synthesis Autoclave Reactor, SS316 Reactor, 20l Rotovap, Stainless Steel Jacketed Reactor
Previous
Inert Glove BoxNext
Germfree Glove BoxSend Inquiry