Autoclave Teflon Liner
(1)25ml/50ml/100ml/150ml/200ml/250ml/300ml/400ml/500ml/1000ml---PTFE≤ 220°C
(2)25ml/50ml/100ml/150ml/200ml/250ml/300ml/400ml/500ml/1000ml---PPL≤ 280°C
***Price List for whole above, inquire us to get
2. Customization:
(1)Design support
(2)Directly supply the Senior R&D organic intermediate, shorten your R&D time and cost.
(3)Share the advanced purifying technology with you
(4)Supply the high quality chemicals and analysis reagent
(5)We want to assist you on Chemical Engineering (Auto CAD, Aspen plus etc.)
3. Assurance:
(1)CE and ISO certification Registered
(2)Trademark: ACHIEVE CHEM(since 2008)
(3)Replacement parts within 1-year for free
Description
Technical Parameters
The naming of Autoclave Teflon Liner can be explained from different perspectives. Literally, Autoclave refers to a high-temperature and high-pressure sterilization device, while Teflon Liner refers to a container or bag made of Teflon material used to carry items to be sterilized. Therefore, Autoclave Teflon Line can be understood as an autoclave that performs sterilization treatment in a high-temperature and high-pressure environment, using containers or bags made of Teflon material to carry the items to be sterilized.
In addition, from a professional perspective, the naming of Autoclave Teflon Line can also reflect its professional field and purpose. Autoclave is a term widely used in industries such as pharmaceuticals, healthcare, biochemistry, and environmental protection. It refers to a high-temperature and high-pressure sterilization equipment used to sterilize various items. Teflon Liner refers to a container or bag made of Teflon material, usually used to carry items to be sterilized during high-temperature and high-pressure sterilization processes. Therefore, Autoclave Teflon Line can be understood as a device that uses containers or bags made of Teflon material for sterilization treatment during the high-temperature and high-pressure sterilization process.
We provide Autoclave Teflon Liner, please refer to the following website for detailed specifications and product information.
Product: https://www.achievechem.com/chemical-equipment/autoclave-teflon-liner.htm
Product Introduction

Autoclave Teflon Liner is a device used for high-temperature and high-pressure sterilization, which has broad application prospects and plays an important role in industries such as pharmaceuticals, healthcare, biochemistry, and environmental protection.
Construction of Autoclave Teflon Line:
Autoclave Teflon-Liner is made of Teflon material, usually made of high-density Teflon series materials such as polytetrafluoroethylene (HDPE) or polytetrafluoroethylene propylene (FEP). This material has excellent chemical inertness, high temperature resistance, and low friction coefficient, which can resist the erosion of various chemicals while ensuring the normal operation of the equipment.
structure
● Cylinder: The cylinder is the main component of Autoclave Teflon--Liner, usually made of high-strength, corrosion-resistant polyvinylidene fluoride (PVDF) or high-density polytetrafluoroethylene (HDPE). This material has excellent high-temperature resistance and chemical stability, and can resist the erosion of various chemical substances. The cylinder is designed in a cylindrical shape to maximize space utilization and facilitate cleaning and disinfection.
Inside the cylinder, there is usually a support structure set up to support and fix the items to be sterilized. These supporting structures can be orderly arranged reinforcing ribs or metal brackets, designed to ensure uniform heating and pressure transfer of the items during the sterilization process.
● Lid: The lid is the top component of the Autoclave Teflon-Liner, which closely fits with the cylinder to form a closed space. The lid is usually equipped with components such as a pressure control system and temperature sensors for monitoring and controlling the sterilization process. The pressure control system can include components such as a pressure controller, pressure gauge, safety valve, etc., used to control the pressure inside the equipment and issue an alarm when the pressure is too high or too low to ensure the safety of the equipment and experimental personnel.
● Seals: Seals are a crucial part of the Autoclave Teflon-Liner, located between the cylinder and cover to prevent high-temperature and high-pressure gases from entering the equipment. Seals are usually made of materials such as silicone or fluororubber to ensure good sealing performance. At the same time, the sealing element also has a certain degree of high temperature resistance and chemical corrosion resistance, which can resist the erosion of various chemical substances generated during the high-temperature and high-pressure sterilization process.
● Heating system: The heating system is the core component of Autoclave Teflon-Liner, typically consisting of electric heating elements, sensors, and temperature control systems. The electric heating element is made of materials such as stainless steel or nickel alloy, which can resist oxidation and other chemical erosion under high temperature and pressure conditions. The heating system heats the items to be sterilized to the required temperature and maintains a constant temperature to achieve sterilization effect.
The temperature control system precisely controls the temperature of heating elements through temperature sensors and control circuits. It can automatically adjust the power output of the heating element based on the temperature curve set by the user to maintain the temperature fluctuation of the equipment within an acceptable range. At the same time, the temperature control system can also monitor and alarm abnormal temperature situations in real time to prevent equipment overheating or overcooling from adversely affecting the sterilization effect.
● Pressure control system: The pressure control system is a key part of Autoclave Teflon-Liner, usually composed of pressure sensors, safety valves, and pressure regulating valves. The pressure control system can control the pressure inside the equipment and issue an alarm when the pressure is too high or too low to ensure the safety of the equipment and experimental personnel.
Pressure sensors are used to monitor the pressure inside the equipment in real-time and convert the pressure signal into an electrical signal output. The safety valve automatically opens when the pressure is too high to release excess pressure and avoid equipment damage. The pressure regulating valve automatically closes when the pressure is too low to prevent external air from entering the equipment and affecting the sterilization effect.
● Cooling system:After the high-temperature and high-pressure sterilization process is completed, the items to be sterilized need to be quickly cooled to room temperature. Therefore, the autoclave teflon liner is also equipped with a cooling system. The cooling system usually consists of cooling coils, condensers, and other components.
The cooling coil is located at the bottom of the cylinder and is used to quickly export high-temperature and high-pressure gas from the equipment and guide it into the condenser. The condenser condenses high-temperature and high-pressure gas into liquid water and discharges it from the equipment, while transferring heat to the external cooling water circulation system. Through this design, Autoclave Teflon-Liner can quickly cool items to room temperature in a short period of time, ensuring sterilization effectiveness and item integrity.
● Control system:The control system is the human-machine interaction interface of Autoclave Teflon-Liner, used to achieve automated control and operation of equipment. A control system usually consists of components such as a control panel, display screen, buttons, and indicator lights.
The control panel usually displays information such as the current working status and set parameters of the device. The display screen can display more detailed information and data, such as real-time monitoring data of temperature, pressure, and control operation interface. Through components such as buttons and indicator lights, operators can easily control the start, stop, heating, cooling, and other operations of the equipment, as well as perform parameter settings and troubleshooting operations.
● Maintenance parts:In order to ensure the long-term stable operation and convenient maintenance of the Autoclave Teflon-Liner, the equipment is also equipped with some maintenance components. These components include drainage valves, drain valves, filters, and other components.
Product Parameter
Hydrothermal Synthesis Reactor
|
Model |
AC122-15 |
AC122-25 |
AC122-30 |
AC122-50 |
AC122-100 |
AC122-150 |
AC122-200 |
AC122-250 |
AC122-300 |
AC122-400 |
AC122-500 |
AC122-1000 |
|
Capacity (mL) |
15 |
25 |
30 |
50 |
100 |
150 |
200 |
250 |
300 |
400 |
500 |
1000 |
|
Material |
Kettle body is stainless steel, the liner is PTFE or PPL. |
|||||||||||
|
Pressure (MPa) |
Less than 3 |
|||||||||||
|
Temp. (°C) |
220/260/280 |
|||||||||||
All kinds of "Hydrothermal Synthesis Reactor", price list, you can choose online HERE
Working principle

● Heating
There are two heating methods for Autoclave Teflon-Liner: direct heating and indirect heating. Direct heating refers to directly heating water to a high-temperature and high-pressure state, while indirect heating refers to indirectly heating items to be sterilized by heating air or water vapor. During the heating process, the temperature inside the equipment will gradually increase. When a certain temperature is reached, water molecules will produce a large number of free radicals, which have strong oxidation-reduction ability and can quickly kill bacteria and viruses.
● Boosting
While heating, Autoclave Teflon-Liner will exhaust the air inside the device and maintain a certain pressure. This high-pressure environment can allow free radicals to better penetrate into the body of microorganisms, thereby accelerating their death. In addition, high-temperature and high-pressure steam can quickly penetrate into the items to be sterilized, achieving better sterilization effects.
● Timing and automatic control
Autoclave Teflon-Liner is equipped with a timer and control system, which can automatically control the temperature, pressure, and time of the sterilization process. When the set time and pressure are reached, the equipment will automatically stop heating and start cooling. This automatic control method can ensure the accuracy and consistency of the sterilization process, while reducing the risk of operational errors and equipment failures.
● Relationship with Teflon Liner
The naming of Autoclave Teflon-Liner includes "Teflon Liner" because it is usually equipped with containers or bags made of Teflon material inside, used to carry items to be sterilized. Teflon is a material with excellent chemical inertness, high temperature resistance, and low friction coefficient, which can resist the erosion of various chemicals and ensure the normal operation of the equipment. At the same time, Teflon material also has advantages such as high corrosion resistance and low friction coefficient, allowing items inside the equipment to be more evenly heated and better protected. Therefore, adding containers or bags made of Teflon material to Autoclave Teflon Liner can further improve the sterilization effect and equipment stability.
Hot Tags: autoclave teflon liner, China autoclave teflon liner manufacturers, suppliers, factory, Short Path Distillation Kit, Teflon Lined Stainless Steel Autoclave, Laboratory Evaporators, High Pressure Hydrothermal Autoclave Reactor, SS Reactor Manufacturer, 50l Rotary Evaporator
Previous
50 Liter Rotary EvaporatorSend Inquiry