50 Ml Teflon Lined Autoclave
(1)25ml/50ml/100ml/150ml/200ml/250ml/300ml/400ml/500ml/1000ml---PTFE≤ 220°C
(2)25ml/50ml/100ml/150ml/200ml/250ml/300ml/400ml/500ml/1000ml---PPL≤ 280°C
***Price List for whole above, inquire us to get
2. Customization:
(1)Design support
(2)Directly supply the Senior R&D organic intermediate, shorten your R&D time and cost.
(3)Share the advanced purifying technology with you
(4)Supply the high quality chemicals and analysis reagent
(5)We want to assist you on Chemical Engineering (Auto CAD, Aspen plus etc.)
3. Assurance:
(1)CE and ISO certification Registered
(2)Trademark: ACHIEVE CHEM(since 2008)
(3)Replacement parts within 1-year for free
Description
Technical Parameters
50 ML Teflon Lined Autoclave is a high-pressure vessel commonly used in processes such as autoclaving or high-pressure sterilization. The inner surface of this type of container is usually covered with a layer of PTFE, also known as Teflon, to increase the corrosion and wear resistance of the container, while reducing the friction coefficient between the inner wall of the container and the vapor. PTFE has high high-temperature resistance and can maintain stability in high-temperature steam environments without deformation or damage. Having a low coefficient of friction, it can reduce the friction between the inner wall of the container and the steam, reduce energy consumption and wear. It has excellent corrosion resistance to most chemical substances and can effectively prevent chemical corrosion on the inner walls of containers. The PTFE lining has a smooth surface and is not easily adhered to materials, making cleaning and maintenance easy and convenient. Due to its excellent material and structural design, the lining of product has a long service life, which can reduce the cost and trouble of replacing equipment.
Product Introduction

50 ML Teflon Lined Autoclave is a cylindrical high-pressure vessel, usually made of high-pressure steel with a layer of PTFE film as the inner lining. The following are common specifications for this type of container:
1. Diameter:
The diameter of it is usually between 100mm and 1000mm, with common specifications such as 250mm, 300mm, 400mm, 500mm, etc. Containers with different diameters are suitable for different processes and production scales.
2. Length:
The length of a container is usually between 250mm and 2000mm, with common specifications such as 500mm, 750mm, 1000mm, etc. The length of the container can be adjusted according to actual process requirements to meet the needs of specific production processes.
3. Material:
The material of the container is usually high-pressure resistant steel, such as stainless steel, carbon steel, etc. Containers made of different materials have different corrosion resistance and high temperature resistance, and should be selected based on actual process requirements.
4. Film thickness:
The thickness of PTFE film is usually between 0.3mm and 0.5mm, and can be adjusted according to actual process requirements. The thickness of the film directly affects the anti-corrosion and wear resistance of the container, and should be selected based on specific application scenarios.
5. Heating element:
It is usually equipped with heating elements to accurately control the temperature inside the container when needed. The power and shape of heating elements can be customized according to actual process requirements to meet the needs of specific production processes.
6. Safety valve:
In order to prevent the container from exploding when the pressure is too high, a safety valve is usually installed at the bottom of the container. The type and specifications of safety valves can be selected based on actual process requirements to ensure timely release of excess steam in case of high pressure, ensuring the safety of containers and operators.
Product Parameter

All kinds of "Hydrothermal Synthesis Reactor", price list, you can choose online HERE
Product usage

50 ML Teflon Lined Autoclave also has extensive applications in the field of biotechnology. The experimental and production processes involved in the field of biotechnology require high-temperature and high-pressure disinfection and sterilization of equipment and equipment to ensure sterile operations and product quality.
In the laboratory, these can be used for high-temperature and high-pressure disinfection and sterilization of experimental equipment, glassware, biological samples, etc. The high-temperature and high-pressure performance of this container can kill bacteria and microorganisms, ensuring the accuracy and reliability of experimental results. In the laboratory, this type of container can also be used for conducting high-temperature and high-pressure chemical reactions and synthesis experiments, such as drug synthesis, genetic engineering, etc.
The field of biopharmaceuticals has very high requirements for equipment sterility, so these is also widely used in the disinfection and sterilization processes of biopharmaceutical factories. This type of container can withstand high temperature and pressure environments, while the internal PTFE film can prevent corrosion of metal walls by chemicals, ensuring aseptic operation and drug quality. In the biopharmaceutical process, there can also be used for production processes such as high-temperature and high-pressure cell culture, drug screening, and drug synthesis.
Genetic engineering is an important branch in the field of biotechnology, involving a large number of experiments and production processes such as cell culture, gene transduction, and cloning. In these processes, high-temperature and high-pressure disinfection and sterilization are necessary operational steps, and product can meet these requirements. This container can be used for high-temperature and high-pressure cell culture, gene transduction, cloning, and other operations in genetic engineering experiments, ensuring the accuracy and reliability of experimental results.
Protein purification is an important experimental process in the field of biotechnology. In this process, various filters, columns, containers and other equipment need to be used, and the disinfection and sterilization of these equipment is one of the important steps to ensure protein purity. It can be used for high-temperature and high-pressure disinfection and sterilization of equipment during protein purification processes, ensuring product quality and reliability.
Cell culture is an important production process in the field of biotechnology, involving a large number of cell culture media, culture containers, and tools. In these processes, high-temperature and high-pressure disinfection and sterilization are necessary operational steps, and product can meet these requirements. This type of container can be used for disinfection and sterilization of the culture medium and container during the cell culture process, ensuring the stability and reliability of cell growth and reproduction.
operation
When using it, first place the required materials into the container and then close the container lid. Next, introduce steam into the container to increase the pressure inside the container. The temperature and pressure of steam can be adjusted according to process requirements. During the steaming process, steam circulates within the container, evenly heating and sterilizing the material. Due to the presence of Teflon film, the friction force between steam and the inner wall of the container is greatly reduced, thereby reducing energy consumption and wear. After the steam pressure process is completed, the steam inside the container will be discharged, and the pressure inside the container will gradually decrease. At this point, the container lid can be opened to remove the materials that have been steamed or sterilized.
The following is the detailed operation process when using this high-pressure container:
1. Preparation stage
Before starting to use product, it is necessary to confirm that the required materials are ready and the container is in a clean and dry state. At the same time, in order to ensure safety during the operation process, operators need to receive relevant training and be familiar with the equipment operation manual.
2. Loading materials
Place the required materials in the quantity and type required by the process into the container of these. It should be noted that the quantity and type of materials should meet the process requirements to ensure the effectiveness of steaming or sterilization. At the same time, it is necessary to ensure that the materials are evenly distributed within the container to avoid accumulation or uneven coverage.
3. Close the container lid
After loading the material, the container lid of these should be closed. The closure of the lid should be tight and firm to ensure that steam does not leak. At the same time, it is necessary to check whether the sealing ring of the container cover is intact. If there is any damage or detachment, it should be replaced in a timely manner.
4. Introduce steam
Introduce steam into the container of the product to increase the pressure inside the container. The temperature and pressure of steam can be adjusted according to process requirements. Generally speaking, the temperature of steam should be controlled between 120-250 ℃ and the pressure should be between 10-20 bar. During the process of introducing steam, operators should pay attention to controlling steam flow and pressure to avoid sudden pressure increase or excessive temperature.
5. Autoclave process
After the steam is introduced, these will begin the steam compression process. During this process, steam circulates within the container, evenly heating and sterilizing the material. Due to the presence of Teflon film, the friction force between steam and the inner wall of the container is greatly reduced, thereby reducing energy consumption and wear. At the same time, due to the action of high pressure, the cellular structure of the material will be destroyed, and microorganisms will be killed, achieving the effect of sterilization.
6. Discharge steam
After the steam compression process is completed, the steam inside the container will be discharged. At this point, operators should pay attention to controlling the speed and pressure of steam discharge to avoid sudden pressure drops or temperature drops. At the same time, it is necessary to ensure that there are no residual materials or moisture during the steam discharge process to avoid affecting subsequent operations.
7. Open the container lid
After the steam is discharged, the container lid of the can be opened. At this point, operators should pay attention to safety and avoid being scalded by the inner wall of the high-temperature container. At the same time, it is necessary to check whether there are any residual materials or moisture inside the container, and if necessary, clean it up in a timely manner.
8. Removing materials
After opening the container lid, materials that have been steamed or sterilized can be removed. It should be noted that the removal of materials should be carried out after the container has cooled to a safe temperature to avoid burns or contamination. At the same time, it is necessary to check whether the appearance indicators of the material, such as color, odor, and shape, meet the requirements. If there are any abnormalities, they should be dealt with in a timely manner.
9. Cleaning and maintenance
After each use of the 50 ML Teflon Lined Autoclave, it is necessary to clean and maintain the container. The cleaning objects include the inner wall, bottom, lid, and steam pipeline of the container. At the same time, it is necessary to check whether the sealing rings, valves, and other parts of the container are intact. If there is any damage or detachment, it should be replaced in a timely manner. In addition, regular maintenance and upkeep of the container is also necessary to extend its service life and ensure safe operation.
Hot Tags: 50 ml teflon lined autoclave, China 50 ml teflon lined autoclave manufacturers, suppliers, factory, 10l Rotovap, Hydrothermal Reactor, Rotary Distillation, Teflon Lined Hydrothermal Autoclave, Jacketed Glass Reactor, 20l Rotovap
Previous
100 ML Teflon Lined AutoclaveSend Inquiry