What Is The Rotary Evaporator?

Nov 24, 2023

Leave a message

Rotating evaporator is a commonly used laboratory equipment, mainly used for concentration, separation, and purification of liquid mixtures. It is widely used in fields such as chemistry, biology, and medicine, and is an indispensable equipment in laboratories.

(linkhttps://www.achievechem.com/chemical-equipment/large-rotary-evaporator.html)


1. The basic structure of a rotary evaporator
The rotary evaporator mainly consists of the following parts: heating pot, rotary bottle, condenser, receiving bottle, and vacuum pump. A heating pot is a device used to heat liquid mixtures, while a rotating bottle is a container that can rotate and evenly heat the liquid mixture. A condenser is a device used to condense evaporated gas into liquid, while a receiving bottle is a device used to collect the condensed liquid. A vacuum pump is used to reduce the pressure inside the system, in order to evaporate the water in the liquid mixture.

evaporator | Shaanxi Achieve chem-tech

2. Working principle of rotary evaporator
The working principle of a rotary evaporator is mainly to heat the liquid mixture through a heating pot, causing the moisture inside to evaporate. The evaporated water will be condensed into liquid by the condenser and then collected into a receiving bottle. Meanwhile, the rotating bottle continuously rotates during the heating process, allowing the liquid mixture to be uniformly heated and improving evaporation efficiency. The vacuum pump plays a role in reducing pressure throughout the entire system, thereby promoting the evaporation of water.
3. Usage of rotary evaporator
(1) Preparation phase
Before using the rotary evaporator, sufficient preparation work is required. In addition to ensuring that the liquid mixture, rotary flask, heating pot, condenser, receiving bottle, and vacuum pump required for the experiment are complete and placed in the appropriate position, it is also necessary to select the appropriate rotary evaporator model and specifications according to the needs of the experiment. During the preparation process, it is necessary to carefully check whether each component is in good condition and replace or repair any damaged or faulty components in a timely manner.
In addition, to ensure the smooth progress of the experiment and the accuracy of the results, corresponding reagents and tools need to be prepared. These reagents and tools include standard accessories for rotary evaporators, such as rotary bottles, heating pots, condensers, receiving bottles, and vacuum pumps, as well as other reagents and tools that need to be used in experiments, such as experimental glassware, valves, pipelines, filters, etc.
(2) Installation phase
Install the rotating bottle on the rotating shaft and place the heating pot below the rotating bottle. Connect the condenser and receiving bottle to the rotating bottle, and connect the vacuum pump to the condenser. Ensure that all connections are sealed to avoid leakage.
The following are the detailed steps:
(2.1) Place the rotating bottle on the rotating shaft of the rotating evaporator, ensuring that the fixing screws of the rotating bottle align with the rotating shaft, and gently rotate the screws clockwise to fix the rotating bottle on the rotating shaft. When fixing the rotating bottle, it is important to ensure its stability and avoid any looseness or detachment during the experiment.
(2.2) Place the heating pot under the rotating bottle, ensuring that the opening of the heating pot closely fits the bottom of the rotating bottle to avoid leakage of liquid mixture during the heating process. The heating pot should be placed on an appropriate surface to ensure its stability and level, in order to avoid tilting or moving during the experiment.
(2.3) Connect the condenser and receiving bottle to the rotating bottle. Use appropriate connecting pipes and interfaces to tightly connect the inlet of the condenser to the top of the rotating bottle, and place the receiving bottle below the condenser to ensure that the connection is tight and airtight. During the connection process, be careful to avoid excessive force or damage to the connection area.
(2.4) Connect the vacuum pump to the condenser. Use appropriate pipes and interfaces to tightly connect the inlet of the vacuum pump to the outlet of the condenser, creating a vacuum environment that helps the liquid mixture evaporate faster. During the connection process, it is necessary to ensure that the inlet of the vacuum pump is tightly attached to the outlet of the condenser to avoid air leakage or blockage of the pipeline.
(2.5) After connecting all components, it is necessary to ensure that all connections are sealed to avoid leakage. You can use a wrench or pliers to gently tighten the connecting parts, and use leak detection agent or soapy water to check whether each connection is tight. During the experiment, it is necessary to regularly check whether there is any looseness or leakage at each connection, and promptly handle and repair it.

20L-Structure-of-RE | Shaanxi Achieve chem-tech

(3) Operation phase
After installing the equipment, experimental operations can begin. Firstly, pour the liquid mixture into a rotating bottle, and then turn on the power of the heating pot to start heating. At the same time, activate the rotation function of the rotary bottle to allow the liquid mixture to be uniformly heated. After heating to a certain extent, turn on the vacuum pump to reduce the pressure in the system and promote the evaporation of water. As the water evaporates, the condensed liquid will gradually collect in the receiving bottle.
(4) End stage
After the experiment is completed, it is necessary to shut down each device in a certain order to ensure safe and correct subsequent processing. The following are the detailed steps:
(4.1) After the experiment is completed, the power supply of the heating pot should be turned off first. The rotation function of the rotating bottle should also be stopped at the same time to ensure that the equipment stops running completely. When turning off the power, ensure that the equipment has completely cooled down to avoid danger or damage caused by excessive temperature.
(4.2) Turn off the power supply of the vacuum pump and condenser. A vacuum pump is used to reduce the pressure inside the system and promote the evaporation of liquid mixtures. After turning off the vacuum pump, the pressure in the system will gradually return to normal pressure. A condenser is used to condense the evaporated gas into a liquid. After turning off the power to the condenser, it will stop working and no longer produce new liquid.
After turning off all equipment power, the collected liquid can be removed for subsequent analysis and processing. When taking liquid, be careful to avoid splashing or inverting the liquid to avoid affecting the experimental results or the environment.
(4.4) During subsequent analysis and processing, operations can be carried out according to the specific requirements and objectives of the experiment. For example, qualitative and quantitative analysis, separation, and purification can be performed. During the operation process, it is necessary to follow the correct experimental norms and operating procedures to ensure the accuracy and reliability of the experimental results.


4. Precautions for rotating evaporators
(1) Attention should be paid to safety when using rotary evaporators, especially when using high temperature or toxic and harmful liquids. Wear laboratory safety protective equipment, such as laboratory clothing, gloves, glasses, etc.
(2) When installing and operating equipment, carefully check whether each connection is secure and sealed to avoid leakage or accidents.
(3) When using a heating pot, be careful not to overheat the liquid mixture to avoid danger such as burning or burning.
(4) When using a vacuum pump, be careful not to pump air into the system to avoid pressure fluctuations or accidents.
(5) After use, the equipment should be cleaned and maintained to ensure its service life and safety.
In summary, rotary evaporator is one of the commonly used equipment in the laboratory, which can be used for concentration, separation, and purification of liquid mixtures. Attention should be paid to safety and operating procedures during use to ensure the accuracy and reliability of experimental results. At the same time, regular maintenance and upkeep of the equipment is also necessary to ensure its service life and safety.