Peristaltic Pump Dispenser
Flow range:0.0053-6000ml/min
2.Basic peristaltic pump:LabM series
Flow range:0.0053-3100ml/min
3.Industrial peristaltic pump
Speed range:0.1-600rpm
Description
Technical Parameters
Peristaltic pump dispenser is one of the core components of peristaltic pump, it is usually called peristaltic pump driver or compression device, its main function is to periodically squeeze and release the elastic hose through the roller, press block or other forms of compression elements. This extrusion and release process makes the fluid in the hose flow forward under the action of pressure, so as to achieve the delivery of fluid. By precisely controlling the rotation speed, direction and extrusion force of the roller or the press block, the distributor can realize the precise adjustment and control of the fluid delivery volume.
The peristaltic pump distributor is usually composed of a motor, a reducer, a transmission mechanism and a roller (or a press block). The motor provides power to drive the speed reducer to rotate, and the speed reducer converts the rotating motion of the motor into the extrusion motion of the roller (or press block) through the transmission mechanism. When the roller (or presser) squeezes the hose, the fluid in the hose is compressed and moves forward; When the roller (or press block) releases the squeeze on the hose, the hose returns to its original state, and the fluid continues to flow forward under the negative pressure in the hose. Fluid is continuously pumped out by continuous extrusion and release.
Parameter














Security issues during debugging process
Electrical safety
Power connection
Make sure to use the power cord that matches the peristaltic pump dispenser and plug it into the power outlet correctly.
Check that power outlets are well grounded to prevent electrical leakage or the risk of electric shock.
Protection against electric shock
Always disconnect the power supply before performing any electrical connection or disconnection operation.
Avoid operating the peristaltic pump distributor in wet conditions to reduce the risk of electric shock.
Electrostatic protection
Wear an ESD bracelet or take other ESD measures when handling electronic components or circuit boards.
Mechanical safety

Prevent splint injury
Do not insert fingers or other objects into the moving parts of the dispenser during debugging.
Make sure the guard or guard for all moving parts is installed in place and secured.

Prevent leakage
Check that the hose and connector of the peristaltic pump distributor are tightly connected to prevent liquid leakage.
When handling toxic, hazardous or flammable liquids, take extra protective measures and ensure that the work area is well ventilated.

Equipment stability
Make sure the device is mounted on a smooth, sturdy surface to prevent the device from tipping over or sliding.
During commissioning, avoid severe shock or vibration to the device.
Safe operation
Follow the operating procedures
Strictly follow the equipment operation manual and debugging guide.
Do not attempt to perform operations that are unauthorized or beyond the capabilities of the equipment.
Personal Protection
Wear appropriate personal protective equipment, such as gloves, goggles, protective clothing, etc.
Wear a gas mask or respirator when handling toxic, harmful or irritating liquids.
Emergency shutdown
Familiar with the position and operation of emergency stop button or switch of peristaltic pump distributor.
When any abnormal situation or potential danger is detected, immediately press the emergency stop button and cut off the power supply.
Environmental safety
Clean the work area
Keep the work area clean and free of debris to avoid slipping, tripping and other accidents.
Regularly clean the peristaltic pump dispenser and the surrounding environment of liquids, dust and debris.
Fire prevention measures
Ensure that the work area is equipped with appropriate fire fighting equipment, such as fire extinguishers, fire hydrants, etc.
When handling flammable liquids, take extra fire precautions and ensure that the work area is away from the source of fire.
Good ventilation
Ensure that the work area is well ventilated to prevent the build-up of toxic, harmful or irritating gases.
In summary, in the process of commissioning the peristaltic pump distributor, it is necessary to pay attention to many aspects of electrical safety, mechanical safety, operational safety and environmental safety. By following operating procedures, wearing personal protective equipment, keeping the work area clean and taking additional protective measures, you can minimize potential risks and ensure that the commissioning process is carried out safely.
Flow calibration-Important steps to ensure accurate flow output
Calibration step

Go to the traffic correction page
First, you need to go to the "Flow correction" page of the peristaltic pump distributor.
Check that the pipe is completely filled (there is no air in the pipe). If the pipe is not filled, start the peristaltic pump to fill the pipe. In flow correction mode, it automatically stops after running for a period of time after starting.
Prepare the measuring vessel
Prepare a container and zero the container weight on an electronic scale.
Place the container at the pump line outlet ready to receive the fluid flowing from the device.


Start peristaltic pump and record flow rate
Press the start and stop button to start the peristaltic pump, after the peristaltic pump automatically stops, measure and record the amount of the pumped material (the unit can be milliliters, grams, kilograms, etc.).
In order to improve the accuracy of the measurement, it is recommended to measure several times and take an average value.
Enter the calibration value
Press Ent key, and cooperate with up and down keys, input the value measured in the previous step as the calibration value.
For example, if the previous step measured a value of 84.0 grams, set the "calibration value" to "84.00".
Then press Esc to exit the traffic correction page.

Precautions
Calibration conditions
When calibrated, the speed is generally not less than 20rpm.
After replacing the new pump tube, it is recommended to run at full speed for a few minutes before calibration, in order to obtain more accurate calibration results.
When the liquid level of the raw material barrel is in the middle position (half the barrel), the calibration effect is better.
01
Re-calibrate
If the flow rate or speed is reset after calibration, and the new value changes significantly from the original value, the calibration should be re-performed.
If the flow is still deviated after a calibration, or the flow deviation occurs after the calibration is put into use for a period of time, it can also be calibrated again using the same method to improve the measurement accuracy.
02
Operation specification
When calibrating the flow, ensure that all connections are tight and leak-free to avoid fluid leakage affecting the measurement results.
During the measurement process, a stable measurement environment should be maintained to avoid interference from external factors to the measurement results.
03
Safety precautions
When performing maintenance or calibration of the peristaltic pump distributor, ensure that the power supply is cut off to avoid electric shock or equipment damage.
When handling corrosive, toxic, or flammable fluids, take appropriate safety measures, such as wearing protective gloves and glasses.
04
Details to be noted
The following aspects should be paid attention to in flow calibration:




Pre-calibration preparation
Confirm pipe status: Before flow calibration, ensure that the pipe is completely filled, that is, there is no air in the pipe. If the pipe is not completely filled, the peristaltic pump should be started to fill until the pipe is filled with fluid.
Prepare measuring tools: Prepare an accurate measuring container and electronic scale for measuring the amount of fluid flowing out of the peristaltic pump dispenser. Ensure that the capacity of the measuring vessel is large enough to accommodate the fluid that flows out during the calibration process.
Calibration process
Set calibration parameters: Enter the flow calibration page of peristaltic pump distributor, and set calibration parameters according to actual needs, such as speed, running time, etc. In general, the calibration speed is generally not less than 20rpm.
Start calibration: Place the measuring vessel at the outlet of the pump tube and press the start stop button to start the peristaltic pump. After the peristaltic pump automatically stops, immediately measure and record the amount of pumped material. In order to improve the accuracy of the measurement, it is recommended to measure several times and take an average value.
Input calibration value: Input the measured average value as calibration value into the flow correction page of the peristaltic pump distributor. Ensure that the entered values are correct to avoid errors in subsequent use.
Post-calibration processing
Check the calibration results: After the calibration is completed, the calibration results should be checked to see if they meet expectations. If there is a large deviation between the calibration result and the actual demand, the calibration should be re-calibrated until the requirements are met.
Record calibration data: the data and results obtained in the calibration process are recorded for subsequent analysis and reference. This helps to understand the performance changes of the peristaltic pump distributor and provides a basis for subsequent maintenance.
Control system maintenance
The maintenance of peristaltic pump dispenser control system is the key to ensure its stable operation and prolong its service life. The following are some suggestions for the maintenance of the peristaltic pump distributor control system:
Check and clean regularly
Power cable and ground cable check
Check the power cord and ground wire of the peristaltic pump distributor regularly to ensure that there is no damage or aging.
If the power cable or ground cable is faulty, replace it in time to avoid potential safety risks.
Check the connection between control panel and motor
Regularly check that the connection between the control panel and the motor is firm to ensure that there is no loose or poor contact.
If the connection is found to be loose, it should be tightened in time to ensure the stability of signal transmission and the normal operation of the motor.
Pump head and hose cleaning
Clean pump heads and hoses regularly to remove residual chemical or biological contaminants.
Use a soft cloth or special cleaning agent to clean, avoid using hard objects or corrosive solutions.
Lubrication and replacement of parts
Transmission component lubrication
The peristaltic pump transmission components are lubricated regularly to reduce friction and wear.
Use suitable lubricating oil and operate according to the instructions to avoid excess or insufficient.
Pump pipe and seal replacement
Regularly check pump pipes and seals (such as hose, O-rings, etc.) for wear or aging.
If the pump pipe is found to be cracked, deformed or blocked, it should be replaced in time to avoid affecting the pumping effect and flow accuracy.
If the seal is damaged, it should also be replaced in time to ensure the tightness of the pump body and prevent liquid leakage.
Software calibration and troubleshooting
Flow control system calibration
The flow control system of the peristaltic pump is calibrated regularly to ensure the accuracy and stability of the flow.
Test with standard solution and adjust pump parameters according to test results.
Troubleshooting and maintenance
When the peristaltic pump distributor fails, it should be investigated and maintained in time.
Check whether the power and cable connections are normal, and whether the motor and control system are operating normally.
If it cannot be solved by itself, professional maintenance personnel should be contacted for inspection and maintenance.
Safety operation and maintenance records
Safe operation
When performing maintenance or troubleshooting, ensure that the power supply is cut off and take appropriate safety measures.
Do not run the device unattended to avoid damage to the device or a fire.
Maintenance records
Record maintenance details of the peristaltic pump distributor, including maintenance time, operations performed and parts replaced.
This helps you quickly learn about the historical maintenance information and provides the basis for subsequent maintenance.
Conclusion
The maintenance of the equipment control system requires a comprehensive consideration of several aspects, including regular inspection and cleaning, lubrication and replacement of parts, software calibration and troubleshooting, and safe operation and maintenance records. Only the operation in strict accordance with the maintenance requirements can ensure the stable operation and prolong the service life of the peristaltic pump distributor.