Column Chromatography Lab
2.Chromatographic Column (Rotation Type)
3.Chromatographic Column (Manual)
***Price List for whole above, inquire us to get
Description
Technical Parameters
Column chromatography is a fundamental technique in chemistry used for the purification of compounds. It is widely employed in research laboratories, educational institutions, and industrial settings for separating mixtures into their individual components. The Column Chromatography Lab Kit is designed to provide users with a comprehensive and efficient toolset for performing column chromatography experiments. This product is ideal for both beginners and experienced researchers, offering a user-friendly experience while maintaining high standards of precision and reliability.
Product Overview
|
|
The Column Chromatography Lab Kit includes all the necessary components to set up and run a column chromatography experiment. The kit is designed to be versatile, accommodating a wide range of applications from simple educational demonstrations to complex research projects. The components are made from high-quality materials to ensure durability and consistent performance. |
Parameter
| Glass Chromatographic Column | ||
| Outer Diameter(mm) | Column Length(mm) | Receiving Flask |
| 100 | 1000 | 1000ml |
| 120 | 1000 | 1000ml |
| 140 | 1000 | 2000ml |
| 150 | 1000 | 2000ml |
| 160 | 1000 | 2000ml |
| 180 | 1000 | 3000ml |
| 200 | 1000 | 5000ml |
| 230 | 1000 | 5000ml |
| 250 | 1000 | 10L |
| 300 | 1000 | 10L |
| Chromatographic Column (Rotation Type) | ||
| Outer Diameter(mm) | Column length(mm) | Receiving Flask |
| 100 | 1200 | 1000ml |
| 120 | 1200 | 1000ml |
| 140 | 1200 | 2000ml |
| 150 | 1200 | 2000ml |
| 160 | 1200 | 2000ml |
| 180 | 1200 | 3000ml |
| 200 | 1200 | 5000ml |
| 230 | 1200 | 5000ml |
| 250 | 1200 | 5L |
| 300 | 1200 | 5L |
| Chromatographic Column (Manual) | |||
| Inner diameter(mm) | Maximum column Tube Height(mm) | Maximum Compression | Working Pressure(bar) |
| 100 | 500 | Full Compression | 5 |
| 150 | 500 | Full Compression | 5 |
| 190 | 500 | Full Compression | 5 |
| 300 | 500 | Full Compression | 3 |
| 460 | 500 | Full Compression | 3 |
| 540 | 500 | Full Compression | 3 |
| 600 | 500 | Full Compression | 3 |
Key Features
◆ High-Quality Glass Column: The kit includes a borosilicate glass column, known for its excellent chemical resistance and thermal stability. The column is available in various sizes to accommodate different sample volumes and separation requirements.
◆ Adjustable Flow Control: The column is equipped with a precision flow control valve, allowing users to regulate the flow rate of the mobile phase with high accuracy. This feature is crucial for achieving optimal separation efficiency.
◆ Durable Stationary Phase Supports: The kit comes with a selection of stationary phase supports, including silica gel, alumina, and other specialized media. These supports are packed in a way that ensures uniform flow and minimizes band broadening.
◆ Comprehensive Accessory Set: The kit includes all necessary accessories such as adapters, connectors, and tubing. These components are designed to fit seamlessly with the column, ensuring a leak-free setup.
◆ Detailed User Manual: A comprehensive user manual is provided, offering step-by-step instructions for setting up and running a column chromatography experiment. The manual also includes troubleshooting tips and safety guidelines.
◆ Safety Features: The kit is designed with safety in mind, featuring components that are resistant to common laboratory chemicals and a design that minimizes the risk of spills and leaks.
Applications
Our chromatography systems are trusted in diverse fields:
◆ Pharmaceutical R&D: Purify APIs (Active Pharmaceutical Ingredients), remove endotoxins, or isolate metabolites.
◆ Natural Product Isolation: Extract alkaloids, flavonoids, or terpenoids from plant/animal sources.
◆ Proteomics & Genomics: Purify His-tagged proteins, plasmids, or mRNA with affinity columns.
◆ Environmental Analysis: Separate pesticides, heavy metals, or PFAS compounds from soil/water samples.
◆ Teaching Labs: Ideal for undergraduate experiments demonstrating separation principles
Selection of Stationary and Mobile Phases
The effectiveness of column chromatography hinges on the appropriate selection of the stationary and mobile phases. The stationary phase should possess several key characteristics:
◆ Uniform Particle Size and Shape: Ensuring particles are within the 60–200 mesh range aids in efficient packing and flow.
◆ High Mechanical Stability and Chemical Inertness: The stationary phase must resist degradation or reaction with solvents or analytes.
◆ Inertness to Acids, Bases, and Solvents: Prevents contamination of the separated compounds.
◆ Cost-Effectiveness and Availability: Practical considerations for widespread use.
◆ Free Flow of Mobile Phase: Facilitates smooth elution.
Silica gel and alumina are the most commonly used stationary phases due to their adsorptive properties and chemical stability.
The mobile phase selection is equally critical and involves:
◆ Solvent Polarity: Matching the polarity of the solvent to the polarity of the compounds to be separated. For instance, hydrocarbons are less polar, while alcohols and water are more polar.
◆ Solubility of Analytes: Choosing solvents that effectively dissolve the analytes to ensure they can migrate through the column.
◆ Compatibility with Stationary Phase: Ensuring the solvent does not degrade the stationary phase.
Common solvents include ethanol, acetone, water, ethyl acetate, petroleum ether, and dichloromethane.
Column Preparation and Packing
|
Setting up the Column Chromatography Lab Kit is straightforward, thanks to the detailed user manual and the intuitive design of the components. Here is a brief overview of the setup process: ◆ Column Preparation: Choose the appropriate stationary phase and pack it into the glass column. Ensure that the packing is uniform to avoid channeling. ◆ Mobile Phase Selection: Select a suitable mobile phase based on the properties of the compounds to be separated. Common solvents include hexane, ethyl acetate, and methanol. ◆ Sample Loading: Dissolve the sample in a small amount of the mobile phase and carefully load it onto the top of the column. ◆ Elution: Open the flow control valve to allow the mobile phase to pass through the column. Collect the eluent in fractions and monitor the separation using a suitable detection method (e.g., UV-Vis spectroscopy). ◆ Fraction Analysis: Analyze the collected fractions to identify and isolate the desired compounds. |
|
Safety Considerations
While the Column Chromatography Lab Kit is designed with safety in mind, it is important to follow proper laboratory practices to minimize risks. Here are some safety tips:
◆ Personal Protective Equipment (PPE): Always wear appropriate PPE, including gloves, safety goggles, and a lab coat.
◆ Ventilation: Perform experiments in a well-ventilated area or fume hood to avoid inhalation of harmful vapors.
◆ Chemical Handling: Handle all chemicals with care, following the manufacturer's guidelines and Material Safety Data Sheets (MSDS).
Troubleshooting Tips
◆ Poor Separation
Cause: Incorrect choice of stationary or mobile phase.
Solution: Adjust the polarity of the mobile phase or try a different stationary phase.
◆ Band Broadening
Cause: Uneven packing of the stationary phase or too high a flow rate.
Solution: Repack the column more carefully or reduce the flow rate.
◆ Air Bubbles in the Column
Cause: Improper packing or sample loading.
Solution: Tap the column gently to dislodge bubbles or repack the column.
◆ Slow Elution
Cause: High viscosity of the mobile phase or excessive packing density.
Solution: Use a less viscous mobile phase or repack the column with a lower density.
Conclusion

The Column Chromatography Lab Kit is an essential tool for anyone involved in chemical separation and purification. With its high-quality components, user-friendly design, and comprehensive support, this kit offers everything you need to perform successful column chromatography experiments. Whether you are a student, educator, or researcher, the Column Chromatography Lab Kit is your reliable partner in achieving precise and efficient separations.
Investing in the Column Chromatography Lab Kit is a step towards achieving accurate and reliable results in your chromatography experiments. With its robust design and comprehensive features, this kit is designed to meet the demands of modern laboratories. Experience the difference with the Column Chromatography Lab Kit and elevate your research and educational endeavors to the next level.
Hot Tags: column chromatography lab, China column chromatography lab manufacturers, suppliers, factory, Laboratory Rotary Evaporator, 50L Jacketed Reactor, Tablet Press Machine, High Pressure Autoclave Reactor, Complete Short Path Distillation Kit, SS Reactor
Previous
Small Scale Column ChromatographySend Inquiry













