UHT Sterilizer With Aseptic Filling Chamber
video

UHT Sterilizer With Aseptic Filling Chamber

Tubular UHT sterilizer with an optional aseptic filling chamber for laboratory and pilot sample production.
Includes PLC control, 50 L/h adjustable flow ,CIP/SIP functions and vertical laminar airflow.
Primary keyword: UHT sterilizer with aseptic filling chamber
CE ISO PED ceritifcate.
Factory price
Professional Installtion guide
SS316L material
Siemens Schneider Electric brand can be customized.
Reply within 2 hours
Resolve the issue within 48 hours.
24/7 online.
Quality and assurance gurranty.
Send Inquiry
Chat Now

Description

Technical Parameters

UHT Sterilizer with Aseptic Filling Chamber for Laboratory and Pilot Sample Production

For food and beverage developers, heat treatment is only one part of a successful product-testing process. After a liquid product has passed through a UHT processing system, the filling stage also needs to be considered. If the objective is to prepare samples for further evaluation, the filling environment and handling method can influence the quality and consistency of the collected samples.

Achieve Chem offers a tubular UHT sterilizer for laboratory and pilot-scale applications, with an optional independent aseptic filling chamber installed downstream of the sterilization equipment. This configuration is designed for users who need to combine thermal processing with a controlled sample-filling operation.

The UHT system has a standard capacity of 20 L/h and an adjustable flow rate of 5–50 L/h. The separate filling chamber uses vertical laminar airflow and incorporates a fan, pre-filter, HEPA filter, ultraviolet lamp and ozone generator. It is intended for batch sample production and laboratory process simulation.

pilot UHT sterilizer 1

Key Features and Benefits

Integrated thermal processing: The tubular UHT system combines product feeding, heating, sterilization, cooling and filling-related operations.

Optional independent filling chamber: The chamber is installed downstream of the UHT sterilizer as a separate working unit.

Vertical laminar airflow: The filling chamber uses a vertical airflow arrangement for its operating area.

Air filtration system: A fan, pre-filter and HEPA filter are used to process incoming air.

Additional air-treatment components: The chamber includes ultraviolet and ozone equipment as described in the original technical information.

Adjustable airflow: Average air velocity is specified as at least 0.4 m/s and adjustable.

Foot-switch operation: Operators can control continuous filling by holding the packaging material and using the foot switch.

CIP and SIP support: The source equipment description states that the complete test line can automatically perform CIP and SIP when configured with the filling chamber.

UHT Sterilizer with Aseptic Filling Chamber 7

Product Overview

The Achieve Chem UHT sterilizer with aseptic filling chamber is intended for laboratories, universities, research institutions and food or beverage manufacturers conducting product development and pilot-scale tests.

In a typical application, a liquid product enters the UHT sterilizer through the feed hopper. A screw pump transfers the product through the heating and processing sections. The equipment uses two heating boiler systems to control preheating and high-temperature heating separately. After the selected thermal treatment, the product passes through the cooling section before being directed toward the filling arrangement.

The optional filling chamber is installed after the UHT sterilizer. It is an independent working unit designed to provide a controlled filling area for processed materials. Its vertical laminar airflow system consists of a fan, pre-filter and HEPA filter. The chamber also includes ultraviolet and ozone components for additional air-treatment functions.

For customers preparing small batches of samples, the chamber uses a foot switch to support continuous filling while the operator holds the packaging material. This arrangement is intended to make sample collection more convenient during laboratory and pilot testing.

The filling chamber is not the same as a complete commercial aseptic packaging line. Packaging compatibility, container sterilization, product sterility, filling validation and the required process controls need to be evaluated for each application. Buyers should confirm the exact filling configuration and validation requirements before placing an order.

aseptic sample filling 2

 

 

 

UHT Sterilizer with Aseptic Filling Chamber 4
UHT Sterilizer with Aseptic Filling Chamber 3 UHT Sterilizer with Aseptic Filling Chamber 1

UHT Sterilizer Technical Specifications

Parameter

Specification

Equipment type

Tubular UHT sterilizer

Standard capacity

20 L/h

Adjustable product flow

5–50 L/h

Minimum experimental capacity

5 L

Feed hopper capacity

≥4 L

Sterilization temperature range

88–150°C

Preheating section

Up to approximately 92°C

Main heating process

Approximately 92–137°C in the described process

Maximum dual-boiler temperature

150°C

Holding-time options

5 s, 10 s, 30 s; customizable

Maximum system working pressure

Up to 10 bar

Product pump

Screw pump

CIP flow rate

1,000 L/h

Cleaning and sterilization

CIP and SIP functions

Product-contact pipe

316L stainless steel

Other equipment materials

Food-grade stainless steel

Control system

PLC touchscreen

Optional functions

Online homogenization and aseptic filling

Power supply

Three-phase AC 380 V ±10%, 50 Hz ±10%

Installed power

≤12 kW

Dimensions

1,300 × 920 × 1,700 mm

Weight

Approximately 220 kg

Aseptic Filling Chamber Specifications

Parameter

Specification

Installation position

Downstream of the UHT sterilizer

Equipment type

Independent filling chamber

Airflow mode

Vertical laminar flow

Average air velocity

≥0.4 m/s, adjustable

Cleanliness level stated in source

Class 100

Referenced standard

Federal Standard 209D Class 100

Air filtration

Fan, pre-filter and HEPA filter

Additional components

Ozone generator and UV sterilizer

Lighting power

20 W

UV lamp power

18 W

Fan power

370 W

Filling operation

Foot-switch-assisted continuous filling

Application

Batch sample production

The Class 100 description is the performance level stated in the supplied equipment information. It should not be interpreted as proof of certification of the entire room, packaging process or finished product.

How the UHT and Filling System Works

1. Product Feeding and Transfer

The liquid product is introduced through the feed hopper, which has a capacity of at least 4 liters. A screw pump transfers the product through the pipeline, with an adjustable flow rate of 5–50 L/h.

2. Preheating and High-Temperature Processing

The first heating section can raise the product temperature to approximately 92°C. The second section provides further heating, with the described process reaching approximately 137°C. The dual-boiler system has a maximum temperature capability of 150°C.

3. Holding and Cooling

The product is maintained at the selected processing condition for the required holding time. Reference holding-time settings include 5, 10 and 30 seconds. The cooling section uses tap water to cool the product toward room temperature. Additional cooling equipment is required if a lower filling temperature is needed.

4. Transfer to the Filling Chamber

After processing, the product is directed toward the downstream filling arrangement. The aseptic filling chamber is an independent unit installed after the UHT sterilizer. The actual piping, valve arrangement and connection method should be confirmed according to the selected system configuration.

5. Sample Filling

The chamber provides a vertical laminar airflow environment. Incoming air passes through the pre-filter and HEPA filter, while ultraviolet and ozone components provide additional air-treatment functions. The operator can hold the packaging material and use the foot switch to support continuous filling for batch sample production.

sterile filling chamber 1

Applications

The combined UHT and aseptic filling configuration can be considered for:

Dairy beverage development: Processing and collecting liquid milk or dairy beverage samples.

Fruit juice testing: Preparing thermally processed juice samples for product evaluation.

Tea beverage development: Producing test samples from different beverage formulations.

Pilot product trials: Evaluating the relationship between thermal processing and downstream sample handling.

Packaging and filling studies: Conducting small-batch filling trials with the selected packaging material.

Customer sample preparation: Preparing processed samples for internal evaluation or customer feedback.

The system is especially relevant when the customer needs to evaluate both the heating process and the downstream filling operation rather than studying thermal treatment alone.

Why the Filling Chamber Matters

When purchasing a UHT processing system, buyers sometimes focus only on heating temperature and capacity. However, sample preparation also involves the downstream filling arrangement.

A separate filling chamber provides a defined operating area for filling processed material. Its airflow filtration components and additional UV and ozone equipment are intended to support a controlled filling environment. The foot-switch operation can also simplify repeated sample filling during experimental work.

For customers comparing different equipment configurations, it is important to clarify whether aseptic filling is included in the quotation or supplied as an optional independent unit. The packaging format, container preparation method, product cooling requirements and cleaning procedure should also be discussed before equipment selection.

UHT Sterilizer with Aseptic Filling Chamber 2

Manufacturer Support from Achieve Chem

Achieve Chem supplies laboratory and pilot-scale processing equipment for research and product-development applications. Our engineering team has more than 15 years of experience in equipment-related work.

We communicate directly with customers to understand their product type, processing capacity, target temperature, holding time and filling requirements. Based on these details, we can discuss whether a standard UHT sterilizer configuration is sufficient or whether an optional aseptic filling chamber and online homogenization should be considered.

Achieve Chem provides 13 months of after-sales service. For confirmed quality issues covered by the agreed warranty terms, the factory will arrange repair or replacement. The detailed warranty scope, start date and service conditions should be specified in the purchase agreement.

aseptic UHT system 1

aseptic UHT system 2

sterile filling chamber 2

Frequently Asked Questions

1. Is the aseptic filling chamber included as standard?

The filling chamber is described as an independent unit installed after the UHT sterilizer. The actual supply scope should be confirmed in the quotation. Customers should clearly state whether they need the filling chamber when requesting a proposal.

2. What is the cleanliness level of the filling chamber?

The supplied technical information specifies Class 100 cleanliness and references Federal Standard 209D Class 100. This describes the stated performance level of the filling chamber's operating area, not certification of the entire production environment or finished product.

3. How does the filling chamber filter air?

The chamber uses vertical laminar airflow. A fan moves incoming air through a pre-filter and HEPA filter. The equipment also includes ultraviolet lamps and an ozone generator as additional air-treatment components.

4. Can the filling chamber perform continuous filling?

The source description specifies foot-switch-assisted continuous filling. The operator holds the packaging material and uses the foot switch to operate the filling process. The exact filling speed and packaging compatibility should be confirmed for the intended application.

5. Can the entire test line be cleaned and sterilized?

The source equipment information states that the complete test line can automatically perform CIP and SIP when configured with the filling chamber. Buyers should confirm the detailed piping and cleaning sequence for their selected configuration.

6. Does the system support cold filling?

A cold-filling option is described. The process information identifies approximately 4–5°C cold filling with a chiller. The standard tap-water cooling section is specified to cool the product toward room temperature, so additional cooling equipment may be required.

7. What information is needed to select the right configuration?

Please provide the product type, flow rate, target temperature, holding time, filling temperature, packaging format and whether you require online homogenization. These details help determine the appropriate equipment arrangement.

Request a UHT Sterilizer with Aseptic Filling Configuration

Do you need to process liquid milk, fruit juice, tea beverages or other liquid food samples and collect them through a controlled filling arrangement?

Contact Achieve Chem with your product details and testing objectives. Our team can discuss a suitable UHT sterilizer and optional aseptic filling chamber configuration.

Email: sales@achievechem.com
Phone / WhatsApp: +86-18209268326

Contact Achieve Chem today to discuss your laboratory or pilot-scale UHT processing and filling requirements.

Hot Tags: uht sterilizer with aseptic filling chamber, China uht sterilizer with aseptic filling chamber manufacturers, suppliers, factory

Send Inquiry