Peristaltic Pump 1L Min
Flow range:0.0053-6000ml/min
2.Basic peristaltic pump:LabM series
Flow range:0.0053-3100ml/min
3.Industrial peristaltic pump
Speed range:0.1-600rpm
Description
Technical Parameters
The expression of peristaltic pump 1L min usually refers to the flow rate of peristaltic pump is 1 liter/minute. The flow rate of peristaltic pump refers to the volume of liquid that can be transported by the pump per unit time. Common flow units include milliliters per minute (ml/min), microliters per minute (μl/min), and liters per minute (L/min). In these units, 1L/min means that the volume of liquid flowing through is 1 liter per minute.
The flow range of the peristaltic pump depends on factors such as its design, the size of the pump head and the speed of the motor.In the laboratory, peristaltic pumps are often used to precisely control the transport of liquids, such as solution transport in chemical reactions, medium transport in biological experiments, etc., and the flow rate of 1L/min can meet the needs of many laboratory operations; In industrial production, peristaltic pumps can be used to transport a variety of fluids, such as lubricants, coolants, coatings, etc. The flow rate of 1L/min is suitable for some small production lines or occasions requiring precise flow control; Peristaltic pumps are also widely used in medical equipment, such as hemodialysis, infusion systems, etc., in these applications, the flow rate of 1L/min can meet the liquid delivery needs of patients during treatment.
Parameter














Chemical cleaning
Preparatory phase
Learn about pump materials and dirt types
Confirm the material of peristaltic pump, such as pump shell, pump tube, roller, etc., in order to choose the appropriate cleaning agent.
Analyze the type and nature of dirt, such as grease, oxide, organic matter, etc., to determine the type and concentration of cleaning agent.
Choose the right cleaning agent
Depending on the type of dirt and the material of the pump, choose the right cleaning agent. The cleaning agent should be able to effectively remove dirt, and will not cause corrosion or damage to the pump material.
The cleaning agent can be a water-based cleaning agent, a solvent-based cleaning agent or an acid-base cleaning agent.
Prepare the cleaning solution
Prepare the appropriate cleaning solution according to the cleaning agent instructions.
Pay attention to the concentration, temperature and soaking time of the cleaning solution to avoid damage to the material of the pump.
Cleaning stage
Remove pump head
Remove the peristaltic pump head with the appropriate tool to clean the components inside the pump head.
Pay attention to the safety and details of the disassembly process to avoid damaging the pump components.
01
Immersed parts
Soak the pump parts that need to be cleaned (such as pump tubes, rollers, etc.) in the cleaning solution.
Make sure the part is completely submerged and determine the soaking time according to the cleaning agent's instructions.
02
Scrub and stir
Use a soft brush or sponge to gently scrub the surface of the part to remove attached dirt.
The cleaning solution can be stirred with the appropriate tools to promote the dissolution and removal of dirt.
03
Flushing parts
Rinse parts with clean water or appropriate solvent to remove cleaning solution and dirt residue.
Make sure to rinse well and leave no residue.
04
Reassemble and test

Dry parts
Use a clean wiping cloth or heat gun to dry the parts and ensure that no moisture remains.
Avoid using high temperatures or strong winds to blow directly at the parts, so as not to damage the pump material.

Reassemble the pump head
Reinstall the cleaned and dried parts to the pump head.
Ensure that all components are securely installed and not loose.

Test peristaltic pump
Turn on the power and start the peristaltic pump for test.
Observe pump operation to ensure that there are no abnormal sounds or vibrations.
Check whether the pump flow and pressure meet the requirements.
Precautions




Safety first:
When cleaning the peristaltic pump, be sure to disconnect the power supply to avoid electric shock accidents.
When using cleaning agents, pay attention to their toxicity, flammability and corrosiveness to avoid damage to the skin, eyes and respiratory tract.
Choose the right cleaning agent:
The choice of cleaning agent should be determined according to the type of dirt and the material of the pump.
Avoid using cleaning agents that corrode the pump material.
Control cleaning conditions:
Pay attention to the concentration, temperature and soaking time of the cleaning solution to avoid damage to the material of the pump.
During the cleaning process, the cleaning of the components should be regularly observed to avoid excessive cleaning or insufficient cleaning.
Regular cleaning:
In order to ensure the normal operation of the peristaltic pump and extend its service life, it is recommended to clean the peristaltic pump regularly.
The frequency of cleaning can be determined according to the use and the degree of accumulation of dirt.
Mechanical cleaning
Preparatory work
Power off
Ensure that the peristaltic pump has completely stopped running, and disconnect the power to ensure safe operation.
Tools
Prepare necessary cleaning tools, such as a soft brush, wiping cloth, screwdriver, and pipe pliers.
Remove the pump head
Remove the pump head of the peristaltic pump using tools such as a screwdriver so that the components inside the pump head can be cleaned.
Clean the pump head
Take out the pump tube
Gently take out the pump tube in the pump head with pipe pliers, be careful not to forcibly pull out, so as not to damage the pump head or pump tube.
Turn the pump head over
CTurn the pump head over to clean the inside of the pump head and other components such as rollers.
Brush the pump head
Use a soft brush to carefully brush the inside of the pump head and parts such as the roller to remove attached dirt and residue. Avoid excessive force when brushing, so as not to damage the parts of the pump head.
Clean the pump pipe
Soak the pump pipe: Soak the removed pump pipe in the prepared cleaning solution (such as diluted hydrogen peroxide, deionized water, alcohol, etc.), the soaking time depends on the severity of dirt.
Scrub the pump tube: Use a brush to gently scrub the inner and outer walls of the pump tube to remove attached dirt and residue. Be careful not to use needles or other sharp objects to clean the pump tube, so as not to damage the pump tube.
Rinse and dry
Flush the pump head and pump line: Flush the pump head and pump line with clean water or appropriate solvent to remove cleaning fluid and dirt residue. Make sure to rinse well and leave no residue.
Dry the pump head and pump tube: Use a clean wiping cloth to dry the pump head and pump tube to ensure that there is no moisture residue.
Reassemble
Install the pump tube: Reinstall the cleaned and dried pump tube into the pump head to ensure that the pump tube and pump head fit well.
Fix the pump head: Reinstall the pump head on the peristaltic pump and secure it using tools such as a screwdriver.
Inspection and testing
Check the installation: Carefully check the installation of the pump head and pump pipe to ensure that all components are firmly installed without loosening.
Test peristaltic pump: power on and start peristaltic pump for test. Observe pump operation to ensure that there are no abnormal sounds or vibrations. At the same time, check whether the flow and pressure of the pump meet the requirements.
Precautions
Safety first
When cleaning the peristaltic pump, be sure to disconnect the power supply to avoid electric shock.
Choose the right cleaning solution
Choose the right cleaning solution according to the nature of the dirt and the material of the pump. Avoid using cleaning fluids that corrode the pump material.
Avoid damaging parts
During the cleaning process, avoid using too rough cleaning tools or too strong cleaning force to avoid damaging the parts of the pump.
Regular cleaning
In order to ensure the normal operation of the peristaltic pump and extend its service life, it is recommended to clean the peristaltic pump regularly. The frequency of cleaning can be determined according to the use and the degree of accumulation of dirt.
High pressure water cleaning
Preparatory phase
Equipment inspection
Ensure that the high pressure washer is in good condition and that the power supply and water supply pipes are securely connected.
Check whether the safety valve and protection device of the high pressure washer work properly to ensure the safety of the device.
Safety measures
Wear personal protective equipment, including protective clothing, goggles, earplugs, safety gloves, etc., to prevent personal injury caused by high pressure water and dirt.
Ensure that irrelevant personnel have been evacuated from the site to avoid accidents during cleaning.
Cleaning solution preparation (if required)
According to the type of dirt and the material of the pump, you can choose to add the right amount of cleaning agent to the high pressure water to improve the cleaning effect.
Pay attention to the concentration and compatibility of the cleaning agent to avoid damage to the material of the pump.
Cleaning stage
Remove pump head
Remove the peristaltic pump head with the appropriate tool to clean the components inside the pump head.
Pay attention to the safety and details of the disassembly process to avoid damaging the pump components.
Adjust water pressure and flow
Start the pressure washer and adjust the water pressure and flow to the appropriate range.
The choice of water pressure and water flow should be determined according to the material and dirt type of the pump to avoid damage to the pump.
Cleaning pump head
Aim the high-pressure water nozzle inside the pump head and maintain an appropriate distance (generally 30 to 50cm) to ensure that the jet water evenly covers the target area.
During the cleaning process, the nozzle should be kept relatively perpendicular to the cleaning surface to improve the cleaning effect.
As needed, the inside of the pump head can be flushed several times until the dirt is completely removed.
Cleaning pump pipe
If the pump tube also needs cleaning, the pump tube can be soaked in the cleaning solution (if necessary), and then flush the inner and outer walls of the pump tube with high pressure water.
Pay attention to avoid using needles or other sharp objects to clean the pump pipe, so as not to damage the pump pipe.
Reassemble and test
Dry parts
Use a clean wiping cloth or natural air drying method to dry the pump head and pump pipe and other components.
Make sure the parts are completely dry and free of moisture residue.
Reassemble the pump head
Reinstall the cleaned and dried parts to the pump head.
Ensure that all components are securely installed and not loose.
Test peristaltic pump
Turn on the power and start the peristaltic pump for test.
Observe pump operation to ensure that there are no abnormal sounds or vibrations.
Check whether the pump flow and pressure meet the requirements.
Precautions
Safety first
When cleaning the peristaltic pump, be sure to disconnect the power supply to avoid electric shock accidents.
High pressure water has a strong impact force, pay attention to safety when using, to avoid harm to the human body.
Choose the right cleaning solution
Choose the right cleaning solution based on the type of dirt and the material of the pump.
Avoid using cleaning solutions that corrode the pump material.
Control water pressure and flow
Select the right water pressure and flow rate based on the material and dirt type of the pump.
Avoid excessive water pressure and water flow to damage the pump.
Regular cleaning
In order to ensure the normal operation of the peristaltic pump and extend its service life, it is recommended to clean the peristaltic pump regularly.
The frequency of cleaning can be determined according to the use and the degree of accumulation of dirt.
Hot Tags: peristaltic pump 1l min, China peristaltic pump 1l min manufacturers, suppliers, factory, 20 Liter Rotary Evaporator, Hydrothermal Reactor, Manual Tablet Punching Machine, High Pressure Batch Reactor, Molecular Distillation Unit, Hydrothermal Synthesis Reactor
Previous
Peristaltic Liquid PumpSend Inquiry