Monolithic Chromatography Columns
2.Chromatographic Column (Rotation Type)
3.Chromatographic Column (Manual)
***Price List for whole above, inquire us to get
Description
Technical Parameters
Monolithic chromatography columns are a revolutionary advancement in the field of chromatographic separations, offering enhanced performance and efficiency in analytical and preparative chemistry. Unlike traditional particulate-based columns, monolithic columns feature a continuous, porous polymeric or inorganic monolithic matrix that serves as the stationary phase. This design eliminates the need for packed particles, resulting in lower pressure drops, improved mass transfer, and enhanced stability.
The monolithic matrix is typically synthesized within the column itself, creating a uniform and highly interconnected pore structure. This structure allows for efficient flow of the mobile phase through the column, facilitating rapid separations with minimal backpressure. Additionally, monolithic columns exhibit excellent chemical and thermal stability, making them suitable for a wide range of solvents and temperature conditions.
In general, the device represents a major advance in chromatographic technology and provides scientists with a powerful tool to achieve faster, more efficient and repeatable separation.Their unique design and versatile performance make them ideal for a wide array of analytical and preparative tasks in fields such as proteomics, metabolomics, and pharmaceutical research.
Parameters



Applications
in Liquid Chromatography
High Permeability
One of the key advantages of monolithic columns is their high permeability. Permeability refers to the ability of a fluid to flow through a porous material. In HPLC, high permeability means that the mobile phase (solvent) can flow through the column more easily and quickly.
Reduced Backpressure
High permeability reduces the backpressure in the column, allowing for higher flow rates without compromising column performance. This is particularly important in HPLC systems where high pressures can damage the equipment or lead to inconsistent results.
Improved Mass Transfer
The open pore structure of monolithic columns facilitates better mass transfer between the mobile phase and the stationary phase. This results in more efficient separations and shorter analysis times.
High Throughput
The ability to use higher flow rates without increasing backpressure allows for the analysis of more samples in a shorter period of time, increasing throughput in HPLC applications.
High Efficiency
Another significant advantage of monolithic columns is their high efficiency. Efficiency in chromatography refers to the ability of the column to separate analytes based on their chemical properties.
Uniform Pore Structure
Monolithic columns have a uniform pore structure, which ensures consistent flow and interaction of the analytes with the stationary phase. This leads to improved peak shape and separation efficiency.
Reduced Eddy Diffusion
The open pore structure of monolithic columns reduces eddy diffusion, which is a phenomenon that can broaden peaks and reduce separation efficiency. By minimizing eddy diffusion, monolithic columns provide sharper peaks and better separation of analytes.
Scalability
Monolithic columns can be easily scaled up or down to fit different HPLC systems and applications. This scalability maintains high efficiency across a range of column sizes, making monolithic columns versatile for different separation tasks.
Implications in HPLC
The combination of high permeability and efficiency makes monolithic columns ideal for various HPLC applications, including:
Peptide and Protein Separation
Monolithic columns are commonly used for the separation of peptides and proteins due to their ability to handle high viscosity samples and provide high resolution.
Pharmaceutical Analysis
In the pharmaceutical industry, monolithic columns are used for the analysis of drugs and their metabolites, ensuring accurate and reproducible results.
Environmental Analysis
Monolithic columns are also suitable for the analysis of environmental samples, such as pollutants in water and air, due to their high separation efficiency and stability.
Enhanced Performance in Narrow-Bore Columns
- In narrow-bore columns, the radial diffusion path for analytes is shorter compared to larger columns. monolithic chromatography columns, with their open and interconnected pore structure, facilitate efficient radial diffusion, ensuring that analytes rapidly equilibrate between the mobile and stationary phases.
- This rapid equilibration leads to sharper peaks and improved separation efficiency, especially for analytes with similar chemical properties.
- Eddy diffusion, which can broaden peaks and reduce separation efficiency, is minimized in monolithic columns due to their uniform pore structure. In narrow-bore columns, this effect is further amplified, as the smaller diameter reduces the opportunity for eddy currents to form.
- As a result, monolithic narrow-bore columns provide narrower peaks and better resolution between analytes.
- Monolithic columns have a high surface area per unit volume due to their porous structure. In narrow-bore columns, this high surface area allows for more efficient interactions between analytes and the stationary phase, enhancing separation performance.
- In HPLC, heat generation can affect separation performance, particularly in high-speed separations. Monolithic columns, with their continuous pore structure, facilitate better heat transfer compared to particulate-based columns.
- In narrow-bore columns, this improved heat transfer helps maintain a consistent temperature profile across the column, reducing temperature-related variations in separation efficiency.
- Monolithic columns exhibit lower pressure drop compared to particulate-based columns, especially at high flow rates. In narrow-bore columns, this low pressure drop allows for the use of higher flow rates without compromising column integrity or separation performance.
- Higher flow rates translate to shorter analysis times and increased throughput, making monolithic narrow-bore columns ideal for high-speed separations.
|
|
|
in Gas Chromatography
In gas chromatography (GC), monolithic columns, although less prevalent compared to their use in liquid chromatography, offer unique advantages in specific applications. Research in this area has focused on the preparation, optimization, and utilization of monolithic capillary columns within GC systems. These columns exhibit several beneficial characteristics, such as enhanced separation efficiency and lower backpressure, which can significantly improve the performance of GC analyses.
The preparation of monolithic capillary columns for GC involves several critical steps, including the selection of appropriate porous materials, the formulation of the monomer solution, and the polymerization process. Monolithic materials are typically composed of highly cross-linked polymers or inorganic matrices that provide a continuous porous structure within the column. This structure allows for efficient separation of analytes based on their interactions with the stationary phase and their diffusion through the pores.
Once prepared, monolithic columns require optimization to ensure maximum performance in GC applications. This may involve adjusting the column dimensions, the porosity and pore size distribution of the monolithic material, and the choice of stationary phase chemistry. Optimization also includes fine-tuning the GC operating conditions, such as temperature programming, carrier gas flow rate, and injection techniques, to match the specific requirements of the analytes being separated.
The primary advantages of monolithic capillary columns in GC lie in their improved separation efficiency and reduced backpressure. The continuous porous structure of monolithic materials facilitates faster mass transfer and more efficient chromatographic separations, leading to shorter analysis times and better peak resolution. Additionally, the lower backpressure generated by these columns allows for the use of longer column lengths and/or higher carrier gas flow rates, further enhancing separation capabilities.
The reduced backpressure is particularly beneficial in high-resolution GC applications, where high carrier gas velocities are desired to improve separation efficiency but are often limited by the pressure handling capabilities of the GC instrumentation. Monolithic columns can help overcome these limitations, enabling more demanding separations with high sensitivity and resolution.
Due to their unique properties, monolithic chromatography columns in GC have found applications in various fields, including environmental analysis, food safety, pharmaceutical testing, and petrochemical analysis. In these applications, the ability to achieve high separation efficiency and reduced analysis times is crucial for accurate and reliable results.
Preparation technology
The preparation techniques of monolithic chromatography columns mainly include in-situ polymerization and sol-gel method. The following is an introduction to the preparation techniques of different types of monolithic columns:




Preparation technology of integral columns of organic polymers
Free radical polymerization
Principle: Monomers containing olefin double bonds are mostly used. According to the different polymerization monomers, they can generally be classified into three types: polystyrene type, polyacrylamide type, and polymethacrylate type. During the polymerization reaction process, the molecular weight of the polymer formed by polymerization keeps increasing. When it reaches a certain level, the system undergoes spinodal decomposition to form a double continuous porous structure.
Step:
Monomer selection: Commonly used monomers include acrylate, methacrylate, styrene, etc.
The addition of crosslinking agents and porogens: such as ethylene glycol dimethacrylate, divinylbenzene, etc., is used to increase the mechanical strength and stability of the integral column; Porogens include organic solvents (such as toluene, dodecanol) and water-soluble solvents (such as polyethylene glycol), which are used to regulate the pore structure.
Initiator addition: such as azo diisobutylene, benzoyl peroxide, etc., to initiate the polymerization reaction.
Polymerization reaction: Clean and activate the column tube to ensure good surface properties. The monomer, crosslinking agent, pore-forming agent and initiator are mixed evenly in a certain proportion, injected into the column tube, and a polymerization reaction is initiated at a certain temperature to form an integral column.
Post-treatment: steps such as removing pore-forming agents, column performance testing and modification. The pore size and distribution of the entire column are controlled by changing the type and proportion of the porogenic agent. The surface properties of the entire column are changed by chemical modification methods to improve selectivity and separation performance.
Stepwise polymerization: A new method for preparing monolithic columns using the stepwise polymerization reaction of epoxy and amino in recent years. For instance, the Hosoya group used bisphenol A diglycidyl ether and 4,4 '-diamino-dicyclohexylmethane for addition polymerization at 80-160 ℃ for 4 hours. By adjusting the pore size with PEG of different molecular weights, they obtained porous materials with good three-dimensional structures. Subsequently, they polymerized tri (2, 3-propylene oxide) isocyanate with trifunctional groups with BACM and chiral 1, 2-cyclohexanediamine. The resulting integral column was sub-micron in size, and the column efficiency reached 200,000 plates/m when separating alkylbenzene.
Preparation technology of inorganic silica gel monolithic columns
Principle: It is prepared by the sol-gel method using silicon oxide as the main raw material. The most significant chemical changes in the sol-gel method are the hydrolysis and polycondensation reactions that occur during the transformation from sol to gel. The hydrolysis and polycondensation reactions of alkoxysilanes are a pair of competing reactions that occur simultaneously, and the actual reaction process is more complex.
Step:
Initial reaction: With acid as the catalyst, water-soluble organic polymers play a significant role. The decomposition and gelation of the unstable phase occur almost simultaneously. Due to the hydrolytic polymerization of alkoxysilane, silica gel enriched phase and solvent enriched phase are formed respectively. The silica gel enrichment phase forms a micron-sized silicon framework, and the solvent enrichment phase becomes micron-sized through pores. The ratio of through hole size to skeleton size can be regulated by changing the composition of the initial reactants. The diameter of the structural skeleton is generally 0.5-2μm, and the size of the through holes is 1-8μm.
The specific preparation process: In 1991, the NaKanishi group reported the preparation technology of porous silica gel integral materials: under the condition of the presence of water-soluble organic polymer sodium styrene sulfonate, tetramethoxysilane forms silica gel with different three-dimensional structures under the catalytic action of nitric acid. Subsequently, they used alkoxysilane in the presence of organic polymers such as polyacrylic acid or polyethylene oxide, with nitric acid as the catalyst, to prepare monolithic silica gel materials, and conducted in-depth discussions on its preparation mechanism and conditions. In 1996, the Tanaka group first reported the preparation of silica gel monolithic columns for HPLC. They stirred tetramethoxysilane, polyethylene oxide and the catalyst acetic acid at 0 ° C for 0.5 hours to form a gel, which was then injected into a mold tube. The prepared column was reacted overnight at 40℃, then aged, prepared with mesopods, dried and calcined. After that, it was coated with heat-shrinkable polytetrafluoroethylene to form a silica gel integral column, and then chemically modified on the column. The monolithic columns prepared by this method have both micron-sized skeletons and through pores as well as nano-sized mesopores simultaneously. The skeletons and through pores endow the silica gel monolithic columns with strong permeability.
Preparation technology of organic-inorganic hybrid monolithic columns
The organic-inorganic hybrid monolithic column combines the flexibility of the organic phase with the stability of the inorganic phase. Its preparation method is usually based on the preparation of organic polymer monolithic columns or inorganic silica gel monolithic columns, and introduces organic-inorganic composite materials. Through specific chemical reactions or physical mixing methods, the organic and inorganic components are uniformly distributed within the column. Form an integral column structure with special properties.
Hot Tags: monolithic chromatography columns, China monolithic chromatography columns manufacturers, suppliers, factory, Jacketed Glass Reactor Vessel, Single Punch Tablet Press, 1l Short Path Distillation Kit, High Pressure Autoclave Reactor, Hydrothermal Autoclave Reactor, High Pressure Stirred Reactor
Send Inquiry