Metal Glove Box
1)Acrylic Type A glove box: No sample transfer window, must be take it out from the door.
2)Acrylic Type B glove box:There is a sample transfer window, which can protect the gas environment inside the box from being damaged by the outside world.
3)Acrylic Type B glove box:The air in the box can be extracted through the vacuum pump, and then through the high purity dry inert gas into the box, and reach the lower water oxygen content in the box
2.Customization:
1)Single, double, multiple people and other different station boxes.
2)Different shapes, different structures, different applications, different thickness customization options.
3)Doors of different sizes can be opened on any side of the box to facilitate the entry and exit of equipment and accessories.
4)For other optional configurations, contact sales personnel.
***Price List for whole above, inquire us to get
Description
Technical Parameters
Metal Glove Box, as the name suggests, is a glove box made of metal material. It is usually equipped with transparent windows and sealed glove ports, allowing operators to operate internal items through gloves while maintaining a sealed environment. This type of equipment is widely used in scientific research, industry, medical and other fields, especially in situations where sensitive substances need to be processed or sterile operations need to be carried out. It is a device used in specific environments, typically for handling substances that are sensitive to air or moisture, such as chemicals, material samples, electronic components, etc
As a core device for high-precision environmental control, it plays an irreplaceable role in fields such as semiconductors, lithium batteries, and new material research and development. In the future, with the continuous advancement of technology, glove boxes will develop towards higher purification efficiency, more precise environmental control and a higher degree of automation, providing stronger support for technological progress and industrial development.
Parameter
|
|




Structure and Characteristics
Our product




Its structure usually includes a box, glove opening, transparent window, sealing strip, air inlet and outlet and so on. The box is the main structure, usually made of stainless steel and other corrosion-resistant, high-strength metal materials.The glove opening is located at the front or side of the box, allowing operators to operate the interior through the gloves. Transparent windows are usually made of transparent materials such as glass or plastic, making it easy to observe the internal situation. The sealing strip is used to ensure the sealing of the box and prevent external air or moisture from entering. The gas inlet and outlet are used to fill the box with inert gas or perform vacuum operations to regulate the internal environment.
The characteristics of Glove Box mainly include the following:
Good sealing performance:
By using high-quality sealing strips and sealing technology, Glove Box can ensure the sealing of the box, prevent external air or moisture from entering, and protect internal items from contamination.
Easy to operate:
By equipping glove ports and transparent windows, operators can flexibly operate and observe internal items while maintaining a sealed environment.
Environment controllable:
By filling the box with inert gas or performing vacuum operations, the Glove Box can adjust the internal environment to meet different experimental or production needs.
High safety:
Glove Box is usually made of high-strength and corrosion-resistant metal materials, which can withstand certain pressure and impact, ensuring the safety of the operation process.
Application area
Metal Glove Box has a wide range of applications in multiple fields, and the following are some of the main application areas:

Research field
In the field of scientific research, it is commonly used in experimental studies such as materials science, chemistry, biology, etc. For example, in the field of materials science, researchers can use it to study processes such as oxidation and corrosion of materials, as well as explore new methods and properties for material preparation. In the field of chemistry, it is used for the synthesis and separation of compounds sensitive to air or moisture, as well as for research on catalytic reactions. In the field of biology, it is used in cell culture, aseptic operations, and other situations to ensure the sterility and safety of experimental processes.
Industrial sector
In the industrial field, it is also widely used. For example, in the semiconductor manufacturing process, it is used to protect wafers from interference from pollutants such as dust and particles in the air, thereby improving product quality and yield. In the process of electronic component packaging, it is used to package components that are sensitive to air or moisture, such as integrated circuits, capacitors, etc., to ensure their stability and reliability. In addition, it is also used in aseptic operations, drug packaging, and other occasions during the drug production process to ensure the quality and safety of drugs.
Medical field
In the medical field, application is equally important. For example, in the process of cell culture, it is used to provide a sterile, anaerobic, or low humidity environment to ensure the growth and reproduction of cells. During aseptic procedures, it is used for cleaning, disinfecting, and packaging surgical instruments to prevent the risk of infection during the surgical process. In addition, it is also used in vaccine production, blood product preparation, and other occasions to protect products from external pollution and interference.
Specific application cases
Research case: Materials Science Research
In materials science research, it is widely used to study the oxidation, corrosion and other processes of materials, as well as explore new material preparation methods and properties. For example, researchers can use it to study the oxidation process of metal materials, simulate different oxidation environments by controlling parameters such as oxygen concentration and temperature inside the box, and observe the oxidation behavior and performance changes of the material. In addition, researchers can also explore new material preparation methods and properties, such as preparing a thin film material with special properties on the metal surface through chemical vapor deposition and studying its structure and properties.
Industrial case: Semiconductor manufacturing
In the semiconductor manufacturing process, it is used to protect wafers from interference from pollutants such as dust and particles in the air. Wafer is one of the core components in semiconductor manufacturing, and its surface quality directly affects the quality and yield of the product. Therefore, it is necessary to strictly control pollutants such as dust and particles in the environment during the wafer manufacturing process. Ensure the quality of wafers by providing a sealed, oxygen free, and dust-free environment. At the same time, gas analyzers and other equipment can be equipped to monitor real-time parameters such as gas composition and concentration inside the box, to ensure the stability and controllability of the environment.
Medical case: Cell culture
In the process of cell culture, it is used to provide a sterile, anaerobic, or low humidity environment to ensure the growth and reproduction of cells. Cell culture is one of the important methods in biomedical research. By cultivating cells, we can study processes such as cell growth, differentiation, metabolism, and explore new drugs and treatment methods. However, cells have very strict requirements for the environment, requiring control of parameters such as temperature, humidity, and oxygen concentration to maintain their normal growth and reproduction. By providing a stable and controllable environment to meet the needs of cell culture.
At the same time, heating, cooling and other equipment can be equipped to achieve precise temperature control, as well as gas analyzers and other equipment to monitor oxygen concentration and other parameters in real time to ensure environmental stability and controllability.
Comparison with other similar devices
In addition to the metal glove box, there are other similar devices that can be used to process substances that are sensitive to air or moisture. Here are some main comparison objects:
Inert gas protection box
An inert gas protection box is a device that protects internal items from air or moisture interference by filling the box with inert gas (such as nitrogen, argon, etc.). Compared with this box, inert gas protection boxes are usually not equipped with glove ports and transparent windows, so operators cannot directly operate and observe the internal items. In addition, the structure of the inert gas protection box is relatively simple and the cost is also relatively low. However, due to the inability to directly manipulate and observe internal items, inert gas protection boxes may not be able to meet experimental or production needs in certain situations.
Vacuum drying oven
A vacuum drying oven is a device that uses vacuum pumping to reduce the oxygen and moisture content inside the oven, thereby protecting the internal contents. Compared with this box, vacuum drying oven usually has higher drying efficiency and lower oxygen content. However, the vacuum drying oven cannot directly operate and observe the internal items, and strict control of parameters such as vacuum degree and temperature is required during use. In addition, due to the relatively complex structure of the vacuum drying oven, the cost is also high.
Glove type operating box
Metric Roller Chain Sprocket can be used in almost every type of system. Used in conveyor systems such as conveyors, it can transport food, beverages, grain, and other materials from one place to another. Used in the transmission system, it transfers power from a source such as the engine to various components such as the wheels. Therefore, the product is also widely used in fields such as machine manufacturing,agricultural equipment, automobiles, and military equipment.
Electrical system safety
Basic requirements for electrical systems

Power supply stability
The device needs to operate under a stable power supply, usually requiring AC 220V 50Hz power supply.
Ensure that the power supply is securely connected to avoid device faults or security risks caused by poor electrical contact.
Ground protection
Its metal shell should be effectively grounded to prevent electric shock damage caused by electrical equipment leakage.
Periodically check the reliability and integrity of the grounding system.

Safe operation of electrical system

Avoid electrical failure
During the operation, pay attention to the running state of the electrical system. If there is an anomaly, stop the operation in time and contact professionals for maintenance.
Avoid using it in humid or flammable environments to prevent electrical fires or explosions.
Careful operation of electrical equipment
Before operating the control components of the glove box, such as valves and buttons, confirm the operation to avoid electrical faults or potential security risks.
Do not adjust the parameters of electrical equipment at will, unless necessary adjustments are made according to the requirements of experiment or production.

Electrical system emergency treatment
Develop an emergency plan
Develop detailed emergency plans for possible electrical failures or emergencies.
The emergency plan shall include the emergency treatment process, personnel evacuation plan, rescue measures and necessary emergency equipment and materials.


Cut off the power
In the event of an electrical failure or emergency, the power supply should be cut off immediately to prevent the situation from expanding or causing greater damage.
Use the obvious emergency stop button or manually disconnect the power switch to cut off the power.
Electrical system safety protection
Explosion-proof electrical equipment:
If the equipment is used to handle flammable and explosive items, explosion-proof electrical equipment should be used.
Explosion-proof electrical equipment through the special shell structure and circuit design, can prevent the internal spark leakage into the surrounding environment, causing an explosion.
Electrical isolation:
In the electrical system of the metal glove box, an electrical isolation device should be set up to prevent equipment damage or operator injury caused by electrical failure.
Hot Tags: metal glove box, China metal glove box manufacturers, suppliers, factory, Jacketed Glass Reactor, Glass Reactor Laboratory, 50L Jacketed Reactor, Hydrothermal Autoclave 100 Ml, 500ml Short Path Distillation Kit, Hydrothermal Autoclave
Previous
Glove Box Laboratory EquipmentSend Inquiry














