Digital Hotplate Magnetic Stirrer
(1)LCD/Double Knob/Timmer/Heating Plate
(2)Stirring Volume:5L
2. Large Capacity Magnetic Stirrer
(1)Double Knob/DC Brushless Motor/100~240V/5~40°C 80%RH
(2)Stirring Volume:10L/20L/50L
3. Multi Link Magnetic Stirrer:
(1)Double Knob/LCD/100~240V/100~1500RPM
(2)Stirring Volume:3*1/6*1/9*1
4. Mini Magnetic Stirrer:
(1)Miniature Brushless Motor/Stepless Speed Regulation/0~2000RPM/AC 220V 50Hz
(2)Stirring Volume:2L
5. Single Control Multi Connection Magnetic Stirrer:
(1)LED Digital/0~1600RPM/RT±5~99.9°C/220V 50/60Hz
(2)Stirring Volume:4*1/6*1
***Price List for whole above, inquire us to get
Description
Technical Parameters
Digital Hotplate Magnetic Stirrer is a laboratory equipment that combines digital control technology, heating technology, and magnetic stirring technology. It can not only heat liquids or solid-liquid mixtures, but also achieve non-contact stirring through magnetic force, thus avoiding the pollution and wear problems that traditional stirring methods may bring. In addition, digital control technology makes temperature control more precise and stirring speed adjustment more flexible, greatly improving experimental efficiency and accuracy. In chemical, biological, pharmaceutical, material science and other experimental fields, it is an essential experimental equipment.With the advancement of technology, it has gradually replaced traditional heating and stirring equipment with its high precision, easy operation, and intelligence, becoming the new favorite in laboratories.
Application Scenarios And Case Analysis
Chemical reaction
In chemical experiments, it is widely used for temperature control and stirring processes in various chemical reactions. For example, in organic synthesis reactions, precise control of reaction temperature and stirring speed can ensure thorough mixing of reactants and uniform heating, thereby improving reaction yield and purity.
Biological experiments
It also plays an important role in biological experiments. For example, in the process of cell culture, it is necessary to strictly control the temperature and stirring speed of the culture medium to maintain normal cell growth and metabolism. Can provide a stable temperature environment and uniform stirring effect to meet the needs of cell culture.
Material preparation
In the field of materials science, it is used in the preparation process of various materials. For example, in the synthesis process of nanomaterials, precise control of reaction temperature and stirring speed is required to obtain uniform nanoparticles. Can provide stable heating and stirring conditions to ensure the synthesis quality of nanomaterials.
Purchase And Maintenance
► Key points for purchasing
When choosing a digital hotplate magnetic stirrer, the following aspects need to be considered:
Temperature control accuracy:
Select the appropriate temperature control accuracy according to experimental requirements;
Mixing speed range:
Ensure that the mixing speed can meet the experimental requirements;
Heating power:
Select the appropriate heating power based on the size of the experimental container and heating requirements;
Material and corrosion resistance:
Consider whether the materials of the heating plate and stirring element are corrosion-resistant;
Safety:
Check whether the equipment has safety protection measures such as overheating protection and overcurrent protection;
Brand and after-sales service:
Choose well-known brands and suppliers that provide high-quality after-sales service.
► Maintenance methods
In order to ensure its long-term stable operation and extend its service life, regular maintenance and upkeep are required. Here are some common maintenance methods:
Regular cleaning:
After use, wipe the surface of the heating plate and mixer with a soft cloth to avoid using corrosive cleaning agents;
Check the power cord:
Regularly inspect the power cord for damage or aging, and replace it promptly if there are any abnormalities;
Calibration temperature:
Regularly calibrate the equipment with a standard thermometer to ensure temperature control accuracy;
► Storage and protection
Proper storage:
When not in use, the device should be placed in a dry, ventilated, dust-free environment, away from direct sunlight and moisture. At the same time, it is necessary to ensure that the equipment is in a horizontal state to prevent damage to internal components due to long-term tilting.
Dust and dirt prevention:
Cover the equipment with a dust cover or clean cloth to reduce the accumulation of dust and impurities. Regularly clean up the debris around the equipment and keep the work area clean.
► Regular inspection and maintenance
Motor and magnetic system:
Although the magnetic stirring system does not require direct contact, it is still necessary to check whether the magnetic force has weakened or whether the stirring element has worn out after long-term use. If necessary, a new stirrer can be replaced. At the same time, check whether the motor runs smoothly and whether there are any abnormal noises or vibrations.
Heating element:
Check for any signs of damage or aging, such as discoloration, deformation, or burning. If there is any abnormality, please contact the manufacturer for repair or replacement in a timely manner.
Control system:
Check whether the control panel, display screen, buttons and other components are sensitive and reliable, and whether there is any damage or malfunction. Ensure clear and accurate display of numbers to avoid misoperation.
► Precautions
Avoid overload:
When using, do not place heavy or oversized containers on the heating plate to avoid exceeding the load-bearing capacity of the equipment and causing deformation or damage to the heating plate.
Uniform heating:
Try to ensure that the bottom of the container is in full contact with the heating plate to achieve uniform heating. For irregularly shaped containers, appropriate brackets or washers can be used to assist in fixing.
Avoid sudden cooling and heating:
During the heating process, avoid adding a large amount of cold water or ice cubes as a cold source to prevent impact and damage to the heating element.
Professional maintenance:
If the equipment malfunctions or needs maintenance, please be sure to contact professional maintenance personnel or manufacturers for handling. Do not disassemble or repair it yourself.
Digital hotplate magnetic stirrer common faults and solutions
► The mixer does not rotate
1) Check the motor: If the motor is damaged, replace the motor. If the motor is poorly lubricated, it should be refueled and maintained.
2) Check the circuit: Check whether the high-power components on the circuit board are damaged, such as 3DD102, and replace the damaged components if necessary. Check whether the diode in the rectifier circuit is short-circuited, and repair or replace the short-circuited diode.
3) Check the transformer: If the transformer is burned out, replace the transformer.
4) Check stirrer and magnetic field: Make sure the blender is centered in the container and snug against the bottom. Increasing the mixer speed too fast may cause the mixer to decouple from the magnet, and the speed should be increased slowly.
► Heating without heating
1) Check the heating ring: If the heating ring is short-circuited or disconnected, replace the heating ring.
2) Check the fuse: If the fuse is blown, check whether the transformer is burnt or short-circuited before replacing the fuse.
3) Check the temperature sensor: If the temperature sensor is damaged or faulty, replace it.
► Runaway speed
1) Check potentiometer: If the potentiometer is damaged or fails, replace the potentiometer.
2) Check the circuit board: If the circuit board is damaged, replace it.
► Temperature runaway
1) Check the heating tube: If the heating tube is burnt or damaged, replace the heating tube.
2) Check the digital display table: If the digital display is damaged or out of order, replace the digital display.
► Whole machine vibration
1) Check the rotor: If the rotor is unbalanced or damaged, replace the rotor.
2) Check the bearing: If the bearing is damaged or seriously worn, the bearing should be replaced.
► Loud noise
1) Check the motor: If the motor is poorly lubricated or corroded, the motor should be refueled and maintained or replaced.
2) Check mechanical parts: Check for loose or worn mechanical parts and tighten or replace them.
► Leakage of liquid
Check the gasket: If the gasket is aged or damaged, replace the gasket.
► Leakage of electricity
1) Check the heating tube: If the heating tube is aged or damaged, replace the heating tube.
2) Check the power cord: Check whether the power cable is damaged or aged, and replace the power cable if necessary.
► Other precautions
1) Regular maintenance: Clean and maintain the digital hot plate magnetic stirrer regularly to keep the equipment dry and clean.
2) Usage specification: Follow the equipment usage specifications and safety operation rules to avoid faults caused by improper use.
3) Professional maintenance: If you encounter an unsolved fault or need professional maintenance services, contact the device manufacturer or professional maintenance personnel.
How to prevent electric shock




► Use safe sockets
Make sure to use a three-phase safety outlet and check that the outlet is properly grounded. Grounding is an important measure to prevent electric shock, which can ensure that the current can safely flow into the ground when the equipment leaks, rather than through the human body.
► Avoid wet hands
Keep your hands dry when inserting or unplugging the power plug or performing other power related operations. Wet hands increase the risk of electric shock because water conducts electricity.
► Regular inspection of equipment
Check regularly whether the power cord, plug and socket of the magnetic stirrer are in good condition. If it is found to be worn, aged or damaged, it should be replaced immediately to avoid electric shock caused by equipment failure.
► Check before use
Before each use, check whether the control panel, heating plate and stirrer of the magnetic stirrer are working properly. Make sure there are no exposed wires or damaged parts to reduce the possibility of electric shock.
► Compliance with operating procedures
The experiment was carried out in strict accordance with the operating procedures of the magnetic stirrer. Do not arbitrarily change device parameters or perform non-standard operations to avoid electric shock accidents caused by improper operations.
► Wear protective equipment
Wear protective equipment such as lab clothes and gloves when performing experimental operations. These devices can provide additional protection and reduce the risk of electric shock.
► Pay attention to ventilation and drying
Ensure that the laboratory is well ventilated and that the magnetic stirrer and its surroundings are kept dry. Humid environments tend to increase the risk of electric shock because water conducts electricity.
► Cut off the power for maintenance
If the magnetic stirrer fails or needs maintenance, be sure to cut off the power first, and repair under the guidance of professionals. Do not attempt to disassemble or repair the equipment yourself to avoid electric shock or other injury.
► Regular maintenance and maintenance
Regular maintenance and maintenance of the magnetic stirrer, including cleaning equipment, checking for loose or damaged parts, etc. This ensures the proper operation of the equipment and reduces the risk of electric shock due to equipment failure.
How to avoid high temperature contact
Preparations before the operation

Learn about equipment characteristics
Before use, understand the maximum temperature and heating speed of the heating plate of the magnetic stirrer, so as to make correct judgments during operation.
Choose the right container
Choose a container that can withstand high temperatures, such as a glass beaker or a heat-resistant plastic container.
Ensure that the bottom of the container is in full contact with the heating plate to improve heating efficiency and reduce heat loss.

Protective measures during operation
Wear protective gloves
When operating the magnetic stirrer, wear heat protective gloves to prevent direct hand contact with the high temperature heating plate or container.
Use protective cover
If the magnetic stirrer is equipped with a protective cover, it should be covered when in use to reduce heat loss and prevent accidental contact with high-temperature components.
Avoid prolonged exposure to
Try to avoid prolonged contact with the heating plate or container, especially during the heating process. If the container position needs to be moved or adjusted, it should be done after the heating plate has cooled.
Pay attention to heating temperature and time
Set the appropriate heating temperature and time according to the requirements of the experiment to avoid overheating of the equipment or sample denaturation caused by long-term high temperature heating.
Check the temperature of the heating plate regularly to ensure that it does not exceed the set safety range.
Handling after operation
Wait for cooling
After the end of the experiment, do not immediately touch the heating plate or container, should wait for it to cool to a safe temperature before handling.
Cleaning equipment
Wipe the heating plate and housing of the magnetic stirrer with a damp cloth to keep the equipment clean. However, avoid using corrosive solutions or sharp tools during cleaning to avoid damaging the equipment or causing safety hazards.
Storage equipment
Store the magnetic stirrer in a dry, ventilated place, away from direct sunlight and humidity. When storing the device, ensure that the device is turned off and remove the power cable.
Other precautions
Regular inspection of equipment
Check regularly whether the heating plate, power cord and other components of the magnetic stirrer are intact. If damaged, repair or replace them in time.
Compliance with operating procedures
Carry out the experiment in strict accordance with the operating procedures of the magnetic stirrer, and do not arbitrarily change the equipment parameters or carry out non-standard operations.
Train operators
Conduct safety training for personnel using magnetic stirrers to ensure that they understand the proper use of the equipment, safe operation procedures and emergency handling measures.
Hot Tags: digital hotplate magnetic stirrer, China digital hotplate magnetic stirrer manufacturers, suppliers, factory, Single Press Tablet Machine, 20l Rotary Evaporator, Zp17 Rotary Tablet Press, Molecular Distillation Unit, Glass Lab Reactor, Lab Rotary Evaporator
Previous
Types Of Magnetic StirrerSend Inquiry